3.3 Pumped liquids
WARNING
Electric shock
Death or serious personal injury
‐
For indoor use only.
‐
This pump has not been investigated for use in
swimming pool or marine areas.
WARNING
Fire or explosion hazard
Death or serious personal injury
‐
The pump must not be used for the transfer of
flammable liquids such as diesel oil, gasoline and
similar liquids.
The product is suitable for pumping clean, thin, non-aggressive and
non-explosive liquids without solid particles or fibers or mineral oils.
If required, 50% of the volume solution of propylene glycol and
water can be used. However, a decrease in pump performance may
occur due to an increase in the viscosity of the solution. Contact the
manufacturer for information regarding suitability of the pump for
pumping other liquids.
The pump is designed to circulate water from 36 to 230 °F (2 to 110
°C) up to a maximum pressure of 175 psi (12 bar).
3.4 Identification
3.4.1 Nameplate
XXX XX: XXXXXXXXXXX
Made in XXXXXXX
Model: X
XXX°F / XXX°C
Max ambient temp:
XXX°F / XXX°C
Max water temp:
GFXXX
Non-submersible pump
Pompe non immergée
Electronically Protected
PN:XXXXXXXX
SN:XXXXXXXX
PC:XXXXXXX
Grundfos Holding A/S
DK -8850 Bjerringbro
Denmark
Enclosure type 2
Boitier de type 2
1Ph 115V 60Hz
Max
Min
X.XX
X.XX XX
XX
Watt
Amp
7
8
9
10
11
12
14
15
17 16 13
18
19
1
2
3
4
5
6
TM082374
Pos.
Description
1
Product number
2
Serial number
3
Factory code and production code (year and week)
4
Data matrix
5
Grundfos address
6
Country of origin
7
Pump model
8
Max. ambient temperature
9
Max. liquid temperature
10
Combined legal product code
11
Enclosure class
12
Number of phases and voltage
13
Frequency
14
Max. current consumption
15
Min. current consumption
16
Max. power consumption
17
Min. power consumption
18
Approvals
19
FCC radio approval ID
Related information
4.1 Inspecting the product
7. Electrical connection
6