9
English (US)
5.4 Identification
5.4.1 Nameplate
Fig. 3
Nameplate
5.5 Approvals
5.5.1 cULus approval
ALPHA1 26-99/ALPHA2 26-99 pumps for the
North American market are UL approved
(E96215 vol. 1 and MH26400). To identify which
models are approved, find a list with the codes
in section
.
Fig. 4
Left: UL approval mark for water-
circulation pumps. Right: UL
approval mark for drinking-water
system components made of
stainless steel.
TM
07
033
6
491
7
Pos. Description
1
Type designation
2
Voltage [V]
3
Frequency [Hz]
4
Approval mark UL
5
Input power P1 [W] at maximum and
minimum performance
6
Rated current [A] at maximum and
minimum performance
7
Speed
8
Enclosure class
9
Product number
10
Production code (YYMM)
11
Country of origin
12
Control signal
13
Direction of rotation
14
Code for UL Listed pumps
15
Maximum system pressure [psi]
16
Maximum water temperature [°F]
17
Maximum ambient temperature [°F]
18
Application
19
Customer type code
TM
0
7
0
539
0
218
CAUTION
Description of hazard
Minor or moderate personal injury
- cULus listed pumps are tested and
evaluated with water only.
WATER QUALITY
Drinking water system component
NSF/ANSI 61
MH26400
NSF/ANSI 372
Water circulation pump
99K4
Содержание TM07 2122 2818