5. Product introduction

5.1 Product description

ALPHA1 26-99/ALPHA2 26-99 circulator pumps 
are of the canned-rotor type. Pump and motor 
form an integral unit without shaft seal, with only 
one gasket for sealing and four screws for 
fastening the stator housing to the pump 
housing. The bearings are lubricated by the 
pumped liquid.

5.1.1 ALPHA2 26-99 - internally controlled

These circulator pumps are designed for 
systems with variable flow rates, where the 
pump is internally controlled via a user interface. 
Speed control can reduce the power 
consumption considerably. In addition, speed 
control is required to control the performance of 
a system.

Fig. 1

ALPHA2 26-99

5.1.2 ALPHA1 26-99 - externally controlled

These circulator pumps are remote-controlled 
via a low-voltage 0-10 VDC signal by a system 
controller integrated in a boiler or a building 
management system (BMS).

Fig. 2

ALPHA1 26-99

5.2 Applications

ALPHA1 26-99/ALPHA2 26-99 circulator pumps 
are designed for circulating liquids in heating 
and air-conditioning systems. They are suitable 
for cold-water applications in the stainless steel 
versions.

5.3 Pumped liquids

For more technical data, see section 

8. Technical data

.

The pump is suitable for the following liquids:

Clean, thin, non-aggressive and non-
explosive liquids without solid particles or 
fibers.

If the pump is installed in a heating system, 
the water must meet the requirements of 
accepted standards on water quality in 
heating systems.

In domestic hot-water systems, the pump 
should be used only for water with a degree 
of hardness lower than approx. 15 grain 
CaCO3/gal (US) (2.5 mmol CaCO3/l). To 
eliminate the risk of lime precipitation, the 
medium temperature must not exceed 
150 °F (65 °C).

Mixtures of water with anti-freezing media 
such as glycol or ethanol down to 14 °F (-
10 °C) with a validated temperature profile. 
Depending on the type of glycol, the mixture 
and the liquid temperature, the viscosity 
increases. The viscosity must not exceed 
10 cSt (10 mm/s

2

).

TM

07 

212

281

8

T

M

07

 2

1

2

4

 28

18

DANGER

Electric shock

Death or serious personal injury
- Do not use the pump in swimming 

pool or marine areas.

DANGER

Flammable material

Death or serious personal injury
- Do not use the pump for flammable 

liquids, such as diesel oil and 
gasoline.

WARNING

Biological hazard

Death or serious personal injury
- In domestic hot-water systems, the 

pump is permanently connected to 
the water mains. Therefore, do not 
connect the pump by a hose.

CAUTION

Corrosive substance

Minor or moderate personal injury
- Do not use the pump for aggressive 

liquids.

Содержание TM07 2122 2818

Страница 1: ...GRUNDFOS INSTRUCTIONS ALPHA 26 99 Installation and operating instructions...

Страница 2: ...service under this warranty the defective product must be returned to the distributor or dealer of Grundfos products from which it was purchased together with proof of purchase and installation date f...

Страница 3: ...ates a hazardous situation which if not avoided will result in death or serious personal injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious personal i...

Страница 4: ...s Fig 1 Control box positions DANGER Electric shock Death or serious personal injury Switch off the power supply before starting any work on the product Make sure that the power supply cannot be accid...

Страница 5: ...al of the relay is able to handle higher inrush currents We recommend to use special inrush relays with silver tin oxide AgSnO contacts Leakage current The pump mains filter causes a leakage current t...

Страница 6: ...injury Switch off the power supply before starting any work on the product Make sure that the power supply cannot be accidentally switched on WARNING Electric shock Death or serious personal injury Th...

Страница 7: ...must be connected to an external main switch with a minimum contact gap of 0 12 inches 3 mm in all poles Grounding or neutralization must be used for protection against indirect contact WARNING Electr...

Страница 8: ...Technical data The pump is suitable for the following liquids Clean thin non aggressive and non explosive liquids without solid particles or fibers If the pump is installed in a heating system the wa...

Страница 9: ...Voltage V 3 Frequency Hz 4 Approval mark UL 5 Input power P1 W at maximum and minimum performance 6 Rated current A at maximum and minimum performance 7 Speed 8 Enclosure class 9 Product number 10 Pr...

Страница 10: ...0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q m h 0 0 0 5 1 0 0 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 Proportional pressure 3 Proportional pressure 2 Proportional pressure 1 Proportional pressure...

Страница 11: ...10 VDC ALPHA1 26 99 circulators are externally speed controlled by an analog 0 10 V DC signal The pump requires a 0 10 V signal on the signal port to control the speed of the pump The pump will run at...

Страница 12: ...d as cable break Rating Value Rated input voltage high level UIH 4 24 V Rated input voltage low level UIL 1 V High level input current IIH 10 mA PWM frequency output open collector f 75 Hz 5 Accuracy...

Страница 13: ...as already been selected Start at the actual setting Press the button for two seconds The pump enters setting mode and the LED starts flashing Each time you press the button the setting changes LEDs 1...

Страница 14: ...uit breaker d Power supply failure Check that the power supply falls within the specified range Normal power supply a The controller has switched off Check the controller and its settings b The pump i...

Страница 15: ...r the pump surface Storage temperature Maximum 158 F 70 C Liquid temperature Maximum continuously 203 F 95 C Minimum 14 F 10 C Inrush current Measured on a flicker network according to IEC 61000 3 3 1...

Страница 16: ...16...

Страница 17: ...0 www grundfos us GRUNDFOS Canada 2941 Brighton Road Oakville Ontario L6H 6C9 Canada Phone 1 905 829 9533 Telefax 1 905 829 9512 www grundfos ca GRUNDFOS M xico Boulevard TLC No 15 Parque Industrial S...

Страница 18: ...com Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2020 G...

Отзывы: