15
English (US)
8. Technical data
8.1 Approval codes
8.2 Operating conditions
Supply voltage
•
1 x 115 V + 10 %/- 10 %, 50/60 Hz.
Motor protection
EP - Electronically Protected
The pump requires no external motor protection.
Enclosure class
CSA enclosure type 2. For indoor use only.
Maximum system pressure
150 psi (1.0 MPa).
Inlet pressure
The minimum inlet pressure must be available at
the pump inlet during operation.
Ambient temperature
Maximum 130 °F (55 °C) near the pump surface.
Storage temperature
Maximum 158 °F (70 °C).
Liquid temperature
•
Maximum (continuously): 203 °F (95 °C).
•
Minimum: 14 °F (-10 °C).
Inrush current
Measured on a flicker network according to IEC
61000-3-3:1994 + A1, + A2, Annex B.
•
115 V: 25.2 A.
Leakage current
< 3.5 mA.
9. Disposing of the product
This product or parts of it must be disposed of in
an environmentally sound way:
1. Use the public or private waste collection
service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
Code
Voltage
Power
Control
mode
GFJNH
115 V
120 W
VDC
GFJOF
115 V
120 W
AUTO
Liquid
temperature
Minimum
inlet pressure
203 °F (95 °C)
> 7 psi (> 0.05 MPa)