Related information

6.1.1 Built-in motor protection

3.3.4 Controllers for SQF pumps

You can connect SQF pumps to the following
controller types:

CIU 903 (up to 2500 W)

CU 200 (up to 1400 W)

IO101

IO102

IO50.

3.3.5 Sizing the submersible drop cable 

Before you install the pump, make sure to use the
right cable size for the submersible drop cable.

The cross-section of the submersible drop
cable must be large enough to meet the
voltage requirements.

How to calculate the maximum cable length

If the power factor (PF) of the motor unit equals 1.0,
you can use this equation to calculate the maximum
cable length:

=

∙ ∆

∙ ∙

 

100

2

TM070522

 

Explanation of the equation 

Symbol Unit 

Description 

MAX

[m] 

Maximum cable length 

U

[V] 

Supply voltage 

ΔU

[%] 

Maximum recommended volt-
age drop in percentage

I

[A] 

Maximum motor current

ρ


mm

2

/m]

Specific resistance of the ca-
ble 

ϥ

[mm

2

Cross-sectional area of the in-
dividual wires in the submersi-
ble drop cable

Maximum motor current

The maximum motor current depends on the motor
properties and electrical installation. According to IEC
60364-5-52:2009 the installation and cable must
be dimensioned for a current that is higher than the
maximum motor current.

Maximum recommended voltage drop

According to IEC 60364-5-52:2009 for installation
in domestic applications, the maximum
recommended voltage drop is 5 % for cable
lengths up to 100 m.

For installation in industrial applications and in
regions where the IEC standard is not applicable,
local regulations may require that a different
maximum value for voltage drop must be used for
the calculation of the maximum cable length.

Specific resistance of the drop cables

The specific resistance of the drop cables supplied by
Grundfos for SQ, SQE and SQF pumps is 0.02 Ω
mm

2

/m.

Maximum cable lengths for Grundfos MSF 3
motors

Calculation of maximum cable length for the different
motor sizes is based on a voltage drop of 5 % and a
supply voltage of 240 V.
If the calculation above cannot be used, go to
Grundfos Product Center for sizing.

Grundfos can supply submersible drop ca-
bles for any type of installation. Please
contact Grundfos for more information.

4. Starting up the product

1. Make sure that the well can yield a quantity of

water at least corresponding to the pump
performance.

2. Submerge the pump completely in the water.

3. Switch on the power supply.

4. Check that the pump delivers water.

a. If the pump does not deliver water, see

information on fault finding.

Related information

9. Fault finding the product

4.1 Resetting the product

1. Switch off the power supply for 1 minute. The

pump is now reset.

2. Switch on the power and start the pump.

5. Handling and storing the product

5.1 Handling the product

See information on lifting the product.

11

English (GB)

Содержание SQF

Страница 1: ...SQF Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ......

Страница 3: ...Suomi FI Asennus ja k ytt ohjeet 117 Fran ais FR Notice d installation et de fonctionnement 132 GR 148 Hrvatski HR Monta ne i pogonske upute 164 Magyar HU Telep t si s zemeltet si utas t s 179 Italia...

Страница 4: ...re 289 Svenska SE Monterings och driftsinstruktion 305 Slovensko SI Navodila za monta o in obratovanje 320 Sloven ina SK N vod na mont a prev dzku 335 T rk e TR Montaj ve kullan m k lavuzu 350 UA 366...

Страница 5: ...ons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and under...

Страница 6: ...the product On receipt of the product do the following 1 Check that the product is as ordered If the product is not as ordered contact the supplier 2 Check that no visible parts have been damaged If a...

Страница 7: ...in water and lifted above the product 1 2 A B TM071581 Horizontal installation Pos Description 1 Dynamic water level 2 Level sensor A Minimum 0 3 m above the level sensor B Cable length below level se...

Страница 8: ...tlet chamber or attach lifting wires to the wire hooks b If manual lifting is not allowed attach lifting wires to the wire hooks and use appropriate lifting equipment Remove the lifting wires before t...

Страница 9: ...straining wire before low ering it into the borehole or basin 1 Note the weight of the product stated on the pump and motor nameplates 2 Follow one of these procedures according to the weight of the p...

Страница 10: ...service partner or a similarly qualified person The cross sectional area of the submersi ble drop cable must be large enough to meet the voltage requirements Never connect the product to an external...

Страница 11: ...stic applications the maximum recommended voltage drop is 5 for cable lengths up to 100 m For installation in industrial applications and in regions where the IEC standard is not applicable local regu...

Страница 12: ...duct 8 Taking the product out of operation 10 2 Mechanical data 6 Product introduction 6 1 Product description The SQF pump range comprises two pump technologies helical rotor pump 3 for high heads an...

Страница 13: ...ils If the pump is used with potentially toxic liquids it can no longer be used for drinking water In case of maintenance be sure to always use original parts to maintain the initial hygienic characte...

Страница 14: ...pe and size of connecting thread 6 Pump unit 7 Year Week Pos Description 8 P1 Factory code 9 Production country 10 Serial number 11 Direction of rotation 12 Arrow for direction 13 Free area for 2D cod...

Страница 15: ...operating temperature F 10 Insulation class 11 Power factor 12 Rated speed min 1 13 Enclosure class 14 Motor net weight kg lb 15 Year Week 16 P1 Factory code 17 Country of origin 18 Built in temperat...

Страница 16: ...switched on accidentally DANGER Magnetic field Death or serious personal injury Persons with pacemakers dismantling this product must exercise caution when handling the magnetic materials embedded in...

Страница 17: ...pump runs but delivers no flow Cause Remedy Low power supply Ensure sufficient power from the power source The outlet valve is closed Open the outlet valve The non return valve is stuck in closed pos...

Страница 18: ...cure suffi cient flow around the mo tor If necessary remove the pump from the bore hole and add a flow sleeve for cooling 9 5 How to check the power supply DANGER Electric shock Death or serious perso...

Страница 19: ...50 or 60 Starting current The motor starting current is equal to the highest value stated on the motor nameplate Leakage current Leakage current does not ex ceed 3 5 mA Power factor PF 1 11 Disposing...

Страница 20: ...85 716 111 Denmark GRUNDFOS DK A S Martin Bachs Vej 3 DK 8850 Bjerringbro Tel 45 87 50 50 50 Fax 45 87 50 51 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterbur...

Страница 21: ...ore Pte Ltd 25 Jalan Tukang Singapore 619264 Tel 65 6681 9688 Faxax 65 6681 9689 Slovakia GRUNDFOS s r o Prievozsk 4D 821 09 BRATISLAVA Tel 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA...

Страница 22: ...334398 www grundfos com Trademarks displayed in this material including but not limited to Grundfos and the Grundfos logo are registered trademarks owned by The Grundfos Group 2022 Grundfos Holding A...

Отзывы: