background image

English (GB)

11

Fig. 3

To ensure sufficient cooling of the motor, it is 
important to observe the maximum liquid 
temperature of 35 °C under all conditions. 

The motor should always be installed above the well 
screen. If a flow sleeve is used, the pump may be 
installed freely in the borehole.

If the actual temperature of the pumped liquid 
exceeds the specified value or the operating 
conditions otherwise fall outside the specified 
conditions, the pump may stop. Please contact 
Grundfos.

5. Electrical connection

5.1 General

The electrical connection should be carried out by an 
authorised electrician in accordance with local 
regulations.

The supply voltage, rated maximum current and 
power factor (PF) appear from the motor nameplate.

The required voltage for Grundfos submersible 
motors, measured at the motor terminals, is - 10 %/
+ 6 % of the nominal voltage during continuous 
operation (including variation in the supply voltage 
and losses in cables).

If the pump is connected to an electric installation 
where an earth-leakage circuit breaker (ELCB) is 
used as an additional protection, this circuit breaker 
must trip out when earth fault currents with DC 
content (pulsating DC) occur.

The earth leakage circuit breaker must be marked 
with the following symbol: 

.

Supply voltage 

1 x 200-240 V - 10 %/+ 6 %, 50/60 Hz, PE.

The current consumption can only be measured by 
means of a true RMS instrument. If other instruments 
are used, the value measured will differ from the 
actual value.

On SQ/SQE pumps, a leakage current of 2.5 mA at 
230 V, 50 Hz, can typically be measured. The 
leakage current is proportional to the supply voltage.

The SQE and SQE-NE pumps can be connected to a 
control box, type CU 300 or CU 301. 

TM0

1

 051

1

2

9

7

Caution

The borehole diameter must be at least 
76 mm (approx. 3").

Caution

Do not let the pump run against a 
closed discharge pipe for more than 
5 minutes. When the discharge pipe is 
closed, there is no cooling flow and 
there is a risk of overtemperature in 
motor and pump.

Liquid

temperature

Borehole 
diameter

Pump 
diameter

Warning

Before starting work on the pump, 
make sure that the power supply has 
been switched off and that it cannot be 
accidentally switched on.

The pump must be earthed.

The pump must be connected to an 
external mains switch with a minimum 
contact gap of 3 mm in all poles. 

If the motor cable is damaged, it must 
be replaced by Grundfos, an authorised 
Grundfos service workshop or similarly 
qualified persons to avoid a hazard. 

Caution

The pump must never be connected to 
a capacitor or to another type of control 
box than CU 300 or CU 301. 
The pump must never be connected to 
an external frequency converter.

Содержание SQE-NE Series

Страница 1: ...on 12 6 1 General 12 6 2 Assembly of pump part and motor 12 6 3 Removal of non return valve 12 6 4 Fitting the cable plug to the motor 13 6 5 Fitting the cable guard 13 6 6 Cable sizing 14 6 7 Fitting...

Страница 2: ...ator As a minimum the generator output must be equal to the motor P1 kW 10 Starting current The motor starting current is equal to the highest value stated on the motor nameplate Power factor PF 1 Mot...

Страница 3: ...ng a screwdriver or a similar tool 4 Inject motor liquid into the motor with a filling syringe or the like 5 To allow possible air to escape move the motor from side to side 6 Refit the filling plug a...

Страница 4: ...arked with the following symbol Supply voltage 1 x 200 240 V 10 6 50 60 Hz PE The current consumption can only be measured by means of a true RMS instrument If other instruments are used the value mea...

Страница 5: ...be used on the clamping faces of the pump part See fig 6 Fig 6 When pump part and motor have been assembled correctly there must not be a clearance between pump part and motor 6 3 Removal of non retur...

Страница 6: ...earance between the motor and the cable plug 6 5 Fitting the cable guard To fit the cable guard proceed as follows 1 Make sure that the submersible drop cable lies flat in the cable guard 2 Place the...

Страница 7: ...Fitting the submersible drop cable It is recommended to join the submersible drop cable and the motor cable by means of a Grundfos cable termination kit type KM For larger cross sections please contac...

Страница 8: ...lation depths Maximum installation depth below the static water level 150 metres See fig 11 Minimum installation depths below the dynamic water level Vertical installation During start up and operatio...

Страница 9: ...switch and diaphragm tank during starting will be lower than the pump cut in pressure set on the pressure switch pcut in This lower pressure is called minimum pressure pmin pmin is equal to the desir...

Страница 10: ...ce tools are available from Grundfos The Grundfos Service Manual is available on request The pumps can be serviced at a Grundfos service centre 9 1 Contaminated pumps If Grundfos is requested to servi...

Страница 11: ...n the electric installation are blown Replace the blown fuses If the new ones blow too the electric installation and the submersible drop cable should be checked b The ELCB or the voltage operated ELC...

Страница 12: ...e is defective Replace the riser pipe i Undervoltage has occurred Check the power supply 4 Frequent starts and stops a The differential of the pressure switch between the start and stop pressures is t...

Страница 13: ...d neutral Connect the voltmeter to the terminals at the connection The voltage should when the motor is loaded be within the range specified in section 5 Electrical connection Large variations in supp...

Отзывы: