10.1 Megging

Megging of an installation incorporating SQ/SQE 
pumps is not allowed, as the built-in electronics may 
be damaged. See fig. 13. 

Fig. 13

3.

The pump runs at 
reduced capacity. 

a)

The drawdown is larger than 
anticipated. 

Increase the installation depth of the pump, 
throttle the pump or replace it by a smaller 
model to obtain a smaller capacity. 

b)

The valves in the discharge pipe 
are partly closed/blocked.

Check and clean/replace the valves, 
if necessary. 

c)

The discharge pipe is partly 
choked by impurities (ochre).

Clean/replace the discharge pipe. 

d)

The non-return valve of the pump 
is partly blocked. 

Pull out the pump and check/replace the 
valve. 

e)

The pump and the riser pipe are 
partly choked by impurities 
(ochre). 

Pull out the pump. Check and clean or 
replace the pump, if necessary. Clean the 
pipes. 

f)

The pump is defective. 

Repair/replace the pump. 

g)

Leakage in the pipework. 

Check and repair the pipework.

h)

The riser pipe is defective. 

Replace the riser pipe.

i)

Undervoltage has occurred.

Check the power supply.

4.

Frequent starts 
and stops. 

a)

The differential of the pressure 
switch between the start and stop 
pressures is too small. 

Increase the differential. However, the stop 
pressure must not exceed the operating 
pressure of the pressure tank, and the start 
pressure should be high enough to ensure 
sufficient water supply. 

b)

The water level electrodes or level 
switches in the reservoir have not 
been installed correctly. 

Adjust the intervals of the electrodes/level 
switches to ensure suitable time between 
the cutting-in and cutting-out of the pump. 
See installation and operating instructions 
for the automatic devices used. If the 
intervals between stop/start cannot be 
changed via the automatics, the pump 
capacity may be reduced by throttling the 
discharge valve. 

c)

The non-return valve is leaking or 
stuck half-open. 

Pull out the pump and clean/replace the 
non-return valve. 

d)

The supply voltage is unstable.

Check the power supply.

e)

The motor temperature gets too 
high.

Check the water temperature.

Fault Cause 

Remedy

T

M

02

 06

89

 50

0

0

C

C

U

U

U

PE

N

L

C

C

Содержание SQE-NE Series

Страница 1: ...on 12 6 1 General 12 6 2 Assembly of pump part and motor 12 6 3 Removal of non return valve 12 6 4 Fitting the cable plug to the motor 13 6 5 Fitting the cable guard 13 6 6 Cable sizing 14 6 7 Fitting...

Страница 2: ...ator As a minimum the generator output must be equal to the motor P1 kW 10 Starting current The motor starting current is equal to the highest value stated on the motor nameplate Power factor PF 1 Mot...

Страница 3: ...ng a screwdriver or a similar tool 4 Inject motor liquid into the motor with a filling syringe or the like 5 To allow possible air to escape move the motor from side to side 6 Refit the filling plug a...

Страница 4: ...arked with the following symbol Supply voltage 1 x 200 240 V 10 6 50 60 Hz PE The current consumption can only be measured by means of a true RMS instrument If other instruments are used the value mea...

Страница 5: ...be used on the clamping faces of the pump part See fig 6 Fig 6 When pump part and motor have been assembled correctly there must not be a clearance between pump part and motor 6 3 Removal of non retur...

Страница 6: ...earance between the motor and the cable plug 6 5 Fitting the cable guard To fit the cable guard proceed as follows 1 Make sure that the submersible drop cable lies flat in the cable guard 2 Place the...

Страница 7: ...Fitting the submersible drop cable It is recommended to join the submersible drop cable and the motor cable by means of a Grundfos cable termination kit type KM For larger cross sections please contac...

Страница 8: ...lation depths Maximum installation depth below the static water level 150 metres See fig 11 Minimum installation depths below the dynamic water level Vertical installation During start up and operatio...

Страница 9: ...switch and diaphragm tank during starting will be lower than the pump cut in pressure set on the pressure switch pcut in This lower pressure is called minimum pressure pmin pmin is equal to the desir...

Страница 10: ...ce tools are available from Grundfos The Grundfos Service Manual is available on request The pumps can be serviced at a Grundfos service centre 9 1 Contaminated pumps If Grundfos is requested to servi...

Страница 11: ...n the electric installation are blown Replace the blown fuses If the new ones blow too the electric installation and the submersible drop cable should be checked b The ELCB or the voltage operated ELC...

Страница 12: ...e is defective Replace the riser pipe i Undervoltage has occurred Check the power supply 4 Frequent starts and stops a The differential of the pressure switch between the start and stop pressures is t...

Страница 13: ...d neutral Connect the voltmeter to the terminals at the connection The voltage should when the motor is loaded be within the range specified in section 5 Electrical connection Large variations in supp...

Отзывы: