TM050033_061
1
Crimping the connectors
TM050034_061
1
Applying heat to the connector
TM050035_061
1
Completed splices
6.6 Riser pipe
WARNING
Sharp element
Death or serious personal injury
‐
When mounting the riser pipe, adapter or hose, wear
personal protective equipment to avoid cutting on
sharp edges on the pump.
Make sure that the riser pipe or hose are properly sized
and selected based on the estimated flow rates and
friction-loss factors.
6.6.1 If an adapter is required
Install the riser pipe to the pipe adapter. Then install the riser pipe
with the adapter to the pump outlet port.
Use a back-up wrench when attaching the riser pipe to the pump.
Make sure that the pump is gripped only by the flats on the top of
the outlet chamber. The body of the pump, cable guard or motor
must not be gripped under any circumstances.
475S
385S
1
2
4
3
TM050036
Pipe adapters
Pos.
Description
1
Riser pipe
2
Pipe adapters
3
Pump outlet
4
or
13
English (US)
Содержание SP 1100S