background image

English (GB)

4

3. Service tools

4. General information

Position numbers of parts (digits) refer to drawings and parts lists; 
position numbers of tools (letters) refer to section 

3. Service 

tools

.

Before dismantling

• Switch off the power supply to the motor.
• Close the isolating valves, if fitted, to avoid draining the 

system.

• Disconnect the supply cable in accordance with local 

regulations.

Before assembly

• Clean and check all parts.
• Replace defective parts by new parts.
• Order the necessary service kits.
• Always replace gaskets and O-rings.

During assembly

• Lubricate and tighten screws and nuts according to section 

2. Tightening torques and lubricants

.

4.1 Cleaning the Sololift2

The Sololift2 is normally kept clean through regular flushing of the 
toilet.
If the Sololift2 is rarely used, we recommend occasional internal 
cleaning which is performed as follows:
1. Disconnect the power supply.
2. Put detergent into the toilet bowl, cabinet shower or 

washbasin. Flush the toilet or turn on the water.

3. Let the detergent work for approximately 5 minutes.
4. Switch on the power supply, and flush the toilet with clean 

water, or turn on the water.

5. Flush the toilet with clean water, or turn on the water again 

until the Sololift2 has pumped.

4.2 Cleaning the units connected

After cleaning the units connected, flush the toilet once more with 
clean water, or turn on the water until the Sololift2 has pumped.

4.3 Periods of inactivity

If the Sololift2 is not to be used for a long period, we recommend 
that you flush the toilet twice with clean water, or turn on the 
water until the Sololift2 has pumped twice. Then disconnect the 
water supply to all units connected.
If there is a risk of frost, drain the tank of water.

A

B

C

D

E

F

Pos.

Designation

For pos.

Further information

A

Screwdriver

301

Straight slot 8.0 mm

B

Screwdriver

-

Straight slot 2.5 mm

C

Screwdriver

-

PH 3

D

Polygrip pliers

45

50 mm opening width

E

Ratchet spanner with socket

44

8 mm

F

Hexagon key

188

4 mm

Warning
Electrical parts must only be serviced by Grundfos or 
an authorised service workshop.

Warning
Use personal protective equipment if there is a risk of 
getting into contact with the pumped liquid.
Observe local regulations.

Содержание Sololift2

Страница 1: ...Sololift2 50 Hz 1 Service instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...9 Replacing the grinder ring 6 5 10 DIP switch settings 6 6 C 3 D 2 7 6 1 Removing the cover 7 6 2 Fitting the cover 7 6 3 Replacing the supply cable 7 6 4 Replacing the capacitor 7 6 5 Replacing the...

Страница 3: ...2 2 2 6 188 Screw M5 x 12 Stainless steel 3 0 4 0 301a O ring NBR Rocol Sapphire Aqua Sil 303a O ring NBR Rocol Sapphire Aqua Sil 306a O ring 95 x 2 5 NBR Rocol Sapphire Aqua Sil 308b Screw 4 7 x 65...

Страница 4: ...the detergent work for approximately 5 minutes 4 Switch on the power supply and flush the toilet with clean water or turn on the water 5 Flush the toilet with clean water or turn on the water again u...

Страница 5: ...ner pos 158 and pull the pressure switch vertically off motor flange pos 156 4 Clean the inner recess of the motor flange using a soft cloth 5 Lubricate pressure switch retainer pos 481 and the sealin...

Страница 6: ...g away from the pressure switch and tighten the screws 14 Check that the grinder head does not touch the grinder ring 15 Clean the sealing face of the tank top and the outer sealing face of the motor...

Страница 7: ...th Rocol Sapphire Aqua Sil 6 Fit the pressure switch in the motor flange and turn it 30 to 45 counter clockwise to lock it 7 C 3 Set the start level by means of the selector switch See fig 1 8 Connect...

Страница 8: ...ricate the O ring and the inner recess with Rocol Sapphire Aqua Sil 8 Fit the motor in the motor flange The motor leads must point in the opposite direction as the cable clamp of the supply cable 9 Fi...

Страница 9: ...e non return flap c Pressure switch defective Replace the pressure switch unit 4 Motor runs but does not evacuate water a Pump or tank blocked Remove blockage b Air lock in pump or vent hole in pump h...

Страница 10: ...2 3 U4 V3 N2 L1 C 3 D 2 WC 1 WC 3 CWC 3 Capacitor Red Motor Capacitor Motor Blue Black Supply cable Blue Blue Supply cable Black Black Black Black Brown Blue Switch Black Brown Yellow and green Yello...

Страница 11: ...English GB 11 9 Exploded views 9 1 WC 1 TM05 0003 0911...

Страница 12: ...English GB 12 9 2 WC 3 TM05 0004 0911...

Страница 13: ...English GB 13 9 3 CWC 3 TM05 0002 0911...

Страница 14: ...English GB 14 9 4 C 3 TM05 0001 0911...

Страница 15: ...English GB 15 9 5 D 2 TM05 0005 0911...

Страница 16: ...16...

Страница 17: ...nam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava iel 60 LV 1035 R ga T lr 371 714 9640 7 149 641 Fakss 371 9...

Страница 18: ...2693 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding...

Отзывы: