3.1.1 Maximum installation depth
3.1.2 Highest tapping point for SBA pumps
Install SBA pumps so that the height between the
pump and the highest tapping point does not exceed
these values:
SBA 3-35: 13 m.
SBA 3-45: 20 m.
Fig. 1
Highest tapping point for SBA
3.1.3 Minimum space
Pumps installed with a float switch require a free
space between the float switch and the wall to
ensure free movability.
Pumps with side inlet require a free space between
the floating inlet strainer and the wall.
If you install the pump in a well or tank, the minimum
free space must be as shown in figs
.
Pumps installed without a float switch require a
space that corresponds to the physical dimensions of
the pump.
SB and SBA pump with a float switch and side
inlet
Fig. 2
Minimum space for SB and SBA pump in
a well or tank
SB HF pump with a float switch
Fig. 3
Minimum space for SB HF pump. This
example shows installation in a well
Product
Maximum installation depth
[m]
SB
10
SBA
10
SB HF
15
T
M
06
76
48
41
16
Max.
13 m/43 ft
Max.
20 m/66ft
SBA 3-35
SBA 3-45
T
M
06
76
44
40
1
6
TM
07
13
99
15
18
Min.
5 cm/2 inch
Min.
10 cm/
4 inch