OIL LUBRICATED BEARINGS
APPENDIX
Remove item (113A) oil fill plug and fill frame with oil to the center of the sight glass.
If
a Trico oiler is used,
follow instructions below in Figure A.
•
Remove adjustment
assembly from oiler.
•
Adjust bars to dimension
"A".
•
Lock Into position.
•
Replace adjustment assembly
in
oiler.
Figure A.
Oil lubricated bearings, Trico oiler only
A high-quality turbine oil with rust and oxidation inhibitors should be used. Under normal operating
conditions, an oil of 300 SSU viscosity at 100° F should be used where pumping temperatures do not exceed
350° F (177°C). Fill frame with oil to the center of the sight glass through oil fill plug (113A). Fill oiler bottle
and replace in oiler housing.
We recommend a breather to be installed in the location
of
the oil
fill
plug.
.
Change oil after 200 hours of operation for new bearings, then every 2000 hours or three months whichever
occurs first.
BEARING FRAME OIL CAPACITY
4852840
Page 35
PUMPS ARE NOT SHIPPED FROM THE FACTORY WITH OIL. RESPONSIBILITY FOR FILL-
ING THE BEARING FRAME WITH THE PROPER TYPE AND AMOUNT OF OIL IS THE
RESPONSIBILITY OF THE USER.
Pump Group
Oiler Size
A
B
STP, MTP, LTP #3 (4 Ounce)
13/16”
½”
XLTP
#5 (8 Ounce)
13/16
”””””
½”
Содержание Peerless Pump 8196 Series
Страница 47: ...Engineering Data 4852840 Page 47...
Страница 48: ...Pump Trouble Shooting Common Pump Operational Problems Page 48 4852840...
Страница 50: ...ModularInterchangeabilityChart Page 50 4852840...
Страница 51: ...STP Exploded Isometric View 4852840 Page 51...
Страница 52: ...MTPExploded IsometricView Page 52 4852840...
Страница 53: ...LTP Exploded Isometric View 4852840 Page 53...
Страница 54: ...XLTP Exploded Isometric View Page 54 4852840...