7.
After the pump, has been operating for a sufficient length of time to bring it up to operating tem-
peratures, the final alignment should be checked. Once the pump has reached operating temperature,
stop the pump, lock out the power source, and immediately remove coupling guard. Disconnect
coupling and check the alignment. Make any necessary adjustments at this time. Reconnect
coupling and replace coupling guard.
NEVER RUN PUMP WITHOUT THE COUPLING GUARD. DISREGARD OF THIS WARNING CAN
RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
(F) Pump Shutdown: Slowly close discharge valve and shut off power to the motor. Lock out motor power
supply to prevent accidental restart when performing inspection or routine maintenance.
4852840
Page 23
WARNING
Содержание Peerless Pump 8196 Series
Страница 47: ...Engineering Data 4852840 Page 47...
Страница 48: ...Pump Trouble Shooting Common Pump Operational Problems Page 48 4852840...
Страница 50: ...ModularInterchangeabilityChart Page 50 4852840...
Страница 51: ...STP Exploded Isometric View 4852840 Page 51...
Страница 52: ...MTPExploded IsometricView Page 52 4852840...
Страница 53: ...LTP Exploded Isometric View 4852840 Page 53...
Страница 54: ...XLTP Exploded Isometric View Page 54 4852840...