8. Technical data
8.1 Operating conditions
Operating range
Single-impeller pumps: 4-30 m
3
/h and head up to 40
metres.
Twin-impeller pumps: 3-5 m
3
/h and head up to 60
metres.
Pumped liquids
Thin, clean, non-aggressive and non-explosive
liquids, not containing solid particles or fibres.
8.1.1 NS
Ambient temperature
40 °C.
Liquid temperature
Maximum flow rate
Maximum head
Maximum operating pressure
Maximum inlet pressure
On request
Other voltages and/or frequencies.
All NS pumps
0 to 35 °C for
domestic use
NS 3-40, NS 4-23, NS 5-33,
NS 5-50, NS 6-30, NS 6-40,
NS 13-18
-10 to +50 °C for
other uses
NS 5-60, NS 30-18,
NS 30-30, NS 30-36
-15 to +110 °C for
other uses
Pump type
[m
3
/h]
NS 3-40
3
NS 4-23
4
NS 5-33
5
NS 5-50
5
NS 5-60
5
NS 6-30
6
NS 6-40
6
NS 13-18
13
NS 30-18
30
NS 30-30
30
NS 30-36
30
Pump type
[m]
NS 3-40
40
NS 4-23
23
NS 5-33
33
NS 5-50
50
NS 5-60
60
NS 6-30
30
NS 6-40
40
NS 13-18
18
NS 30-18
18
NS 30-30
30
NS 30-36
36
Pump type
[bar]
[MPa]
NS 3-40, NS 4-23, NS 5-33,
NS 6-30, NS 6-40, NS 13-18,
NS 30-18
6
0.6
NS 5-50, NS 5-60, NS 30-30,
NS 30-36
8
0.8
Pump type
[bar]
[MPa]
NS 3-40
2
0.2
NS 4-23
3.7
0.37
NS 5-33
2.7
0.27
NS 5-50
3
0.3
NS 5-60
2
0.2
NS 6-30
3
0.3
NS 6-40
2
0.2
NS 13-18
4.2
0.42
NS 30-18
4.2
0.42
NS 30-30
3
0.3
NS 30-36
2.4
0.24