4.2.2 Horizontal installation, NB, NBG
For inspection and repair, allow suitable
clearances for pump or motor removal.
•
Pumps fitted with motors up to and including 4 kW
require a 0.3 m clearance behind the motor.
•
Pumps fitted with motors of 5.5 kW and up require
a 0.3 m clearance behind the motor and at least a
1 m clearance above the motor to allow the use of
lifting equipment.
•
NB pumps with base frame must have the same
clearance as pumps with motors from 5.5 to 200
kW.
A
TM034127
Clearance behind the motor
Motor
Minimum clearance, A
0.25 - 4 kW
0.3 m
A
B
TM077156
Clearance behind and above the motor
Motor
Minimum clearance
A
B
5.5 - 200 kW
0.3 m
1 m
4.2.3 Minimum clearance of MTB
For inspection and repair, allow suitable
clearances for pump or motor removal.
X
TM033547
Motor and pump head removal
Pump
P2
[kW]
Minimum clearance, X [mm]
Motor only
Motor and pump
head
50 Hz
MTB 50-200 3.0
60
140
MTB 65-160
5.5
80
100
7.5
MTB 65-200
11
100
100
15
60 Hz
MTB 50-200
3.0
60
140
4.0
5.5
80
MTB 65-125 7.5
80
100
MTB 65-160
11
110
100
15
19
English (GB)