2. Installing the product
2.1 Mechanical installation
2.2 Tank mounting
The pump is designed for tank mounting in vertical
position. The pump is positioned in a hole cut into
the cover of the tank (upper side) and is secured to
the tank by four hexagon head screws through the
holes in the mounting flange. We recommend that
you fit a sealing gasket between the pump flange
and tank.
Fig. 1
Pump mounting position
2.2.1 Filtration requirements
A filtration system must be installed in the tank
system to avoid that impurities in the liquid block the
pump.
Fig. 2
Example of a filtration system
Observe these instructions for explosion-
proof products.
A blue or grey circle with a white graphical
symbol indicates that an action must be
taken.
A red or grey circle with a diagonal bar,
possibly with a black graphical symbol,
indicates that an action must not be taken
or must be stopped.
If these instructions are not observed, it
may result in malfunction or damage to the
equipment.
Tips and advice that make the work easier.
CAUTION
Hot or cold surface
Minor or moderate personal injury
- Make sure that no one can accidentally
come into contact with hot or cold
surfaces.
MTH pumps must only be mounted
vertically.