background image

3

English (US)

English (US) 

Installation and operating instructions

Original installation and operating 
instructions.

CONTENTS

Page

1. Limited warranty

Products manufactured by Grundfos Pumps 
Corporation (Grundfos) are warranted to the 
original user only to be free of defects in 
material and workmanship for a period of 
24 months from date of installation, but not more 
than 30 months from date of manufacture. 
Grundfos' liability under this warranty shall be 
limited to repairing or replacing at Grundfos’ 
option, without charge, F.O.B. Grundfos’ factory 
or authorized service station, any product of 
Grundfos manufacture. Grundfos will not be 
liable for any costs of removal, installation, 
transportation, or any other charges that may 
arise in connection with a warranty claim.

Products which are sold, but not manufactured 
by Grundfos, are subject to the warranty 
provided by the manufacturer of said products 
and not by Grundfos' warranty.

Grundfos will not be liable for damage or wear to 
products caused by abnormal operating 
conditions, accident, abuse, misuse, 
unauthorized alteration or repair, or if the 
product was not installed in accordance with 
Grundfos' printed installation and operating 
instructions and accepted codes of good 
practice. The warranty does not cover normal 
wear and tear.

To obtain service under this warranty, the 
defective product must be returned to the 
distributor or dealer of Grundfos' products from 
which it was purchased together with proof of 
purchase and installation date, failure date and 
supporting installation data. Unless otherwise 
provided, the distributor or dealer will contact 
Grundfos or an authorized service station for 
instructions. Any defective product to be 
returned to Grundfos or a service station must 
be sent freight prepaid; documentation 
supporting the warranty claim and/or a Return 
Material Authorization must be included if so 
instructed. 

Grundfos will not be liable for any incidental or 
consequential damages, losses, or expenses 
arising from installation, use, or any other 
causes. There are no express or implied 
warranties, including merchantability or fitness 
for a particular purpose, which extend beyond 
those warranties described or referred to above. 
Some jurisdictions do not allow the exclusion or 
limitation of incidental or consequential 
damages and some jurisdictions do not allow 
limitations on how long implied warranties may 
last. Therefore, the above limitations or 
exclusions may not apply to you. This warranty 
gives you specific legal rights and you may also 
have other rights which vary from jurisdiction to 
jurisdiction.

Products which are repaired or replaced by 
Grundfos or authorized service center under the 
provisions of these limited warranty terms will 
continue to be covered by Grundfos warranty 
only through the remainder of the original 
warranty period set forth by the original 
purchase date.

1.

Limited warranty

3

2.

Applications

4

2.1

Pumped liquids

4

3.

Identification

4

3.1

Nameplate

4

3.2

Type key

5

4.

Operating conditions

5

4.1

Temperatures

5

5.

Installation

5

5.1

Mechanical installation

5

5.2

Electrical installation

5

6.

Operation

6

6.1

Startup

6

7.

Maintenance and service

6

7.1

Maintenance

6

7.2

Service

6

8.

Fault finding

7

9.

Technical data

8

9.1

Sound pressure level

8

9.2

Vibration level

8

10.

Disposal

8

Warning

Prior to installation, read these 
installation and operating 
instructions. Installation and 
operation must comply with local 
regulations and accepted codes of 
good practice.

Содержание MTA 110H-180

Страница 1: ...GRUNDFOS INSTRUCTIONS MTA 110H 180 Installation and operating instructions...

Страница 2: ...2...

Страница 3: ...rvice station for instructions Any defective product to be returned to Grundfos or a service station must be sent freight prepaid documentation supporting the warranty claim and or a Return Material A...

Страница 4: ...or instructions that make the job easier and ensure safe operation Pump type Max particle size inch mm MTA 110H 0 16 0 20 4 5 Max kinematic viscosity cSt 90 Warning Do not use the pump for flammable l...

Страница 5: ...plied with built in thermal protection against thermal overload with slow variation In order to protect the motor against short circuit and rapid current raise the motor must be connected to a circuit...

Страница 6: ...rvals to ensure a correct flow of liquid This will also increase the pump life 7 1 3 Periodic checks Make the following checks at regular intervals depending on the conditions and time of operation Ch...

Страница 7: ...ion is loose or faulty Fasten or replace the cable connection d Motor winding is defective Replace the pump e Pump mechanically blocked Remove the mechanical blocking of the pump f Overload setting is...

Страница 8: ...ly sound way 1 Use the public or private waste collection service 2 If this is not possible contact the nearest Grundfos company or service workshop Subject to alterations Enclosure class to IEC 60034...

Страница 9: ...E To be completed if applied substances ar ar ar ar are not e not e not e not e not hazardous Initial Da Initial Da Initial Da Initial Da Initial Date te te te te I her I her I her I her I hereby decl...

Страница 10: ...10...

Страница 11: ...3400 Telefax 1 913 227 3500 Canada GRUNDFOS Canada Inc 2941 Brighton Road Oakville Ontario L6H 6C9 Phone 1 905 829 9533 Telefax 1 905 829 9512 M xico Bombas GRUNDFOS de M xico S A de C V Boulevard TL...

Страница 12: ...0357 www grundfos com The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright...

Отзывы: