It is possible to use the same pump for sampling in several boreholes if the risk of cross-contamination can 

be eliminated.

The MP 1/Redi-Flo2 pump is not designed for the pumping of concentrated oils, chemicals or explosive 

liquids.

When pumping liquids with a density or kinematic viscosity higher than that of water, a motor input power 

higher than the rated power is required. The maximum performance must therefore be reduced by changing 

the frequency.

When the MP 1/Redi-Flo2 pump is used, the regulations covering the handling of hazardous material 

and possible local regulations must be observed.

The MP 1/Redi-Flo2 pump is not designed for continuous operation like for instance remedial pumping. 

Continuous operation may reduce the life of the pump.

2.2 

Technical specifications

Marking:       

 

The MP 1/Redi-Flo2 sampling pump system is CE-marked.

Submersible pump Grundfos MP 1/Redi-Flo2:

Power input:    

 

1.3 kW

Voltage:       

 

3 x 220 V, 400 Hz

Maximum current:  

 

5.5 A

Motor protection:  

 

Built-in thermal switch

Water temperature:    

0 °C to +35 °C

Discharge port:  

 

Rp 3/4

Continuous operation:   

Maximum 500 hours

Net weight:     

 

2.5 kg

Frequency converters:

Supply voltage:  

 

1 x 200-240 V (+/- 10%), 50/60 Hz

Minimum generator size: 

With voltage control:

              

 

• 3.0 kVA (suitable for non-linear loads, minimal value)

             

 

• 4.5 kVA (suitable for non-linear loads, recommended value)

             

 

• 7.5 kVA (not suitable for non-linear loads)

Nominal input current:   

12.9 A

Nominal output current: 

7.0 A

Supply voltage:  

 

1 x 110-115 V (+/- 10%), 50/60 Hz

Minimum generator size: 

With voltage control:

              

 

• 2.2 kVA (suitable for non-linear loads, minimal value)

             

 

• 3.3 kVA (suitable for non-linear loads, recommended value)

             

 

• 5.5 kVA (not suitable for non-linear loads)

Nominal input current:   

21.9 A

Nominal output current: 

5.8 A

Fuse:           

 

10 A

Power factor:    

 

0.65

Connecting cable:  

 

3 x 1.5 mm

2

, 3 m with plug.

Output voltage:  

 

3 x 15.4 V, 25 Hz, to 3 x 235 V, 400 Hz

Motor protection:  

 

Built-in overcurrent protection, set to 6.1 A

Acceleration time:  

 

0 to 400 Hz: Maximum 6 sec

Deceleration time:  

 

400 to 0 Hz: Maximum 6 sec

Enclosure class:  

 

IP66

Ambient temperature:    

–10 °C to +40 °C

Relative air humidity:    

Maximum 95 %

Weight:        

 

8.0 kg (incl. case).

Содержание MP 1 / Redi-Flo2

Страница 1: ...7E Submersible pump Grundfos MP 1 Redi Flo2 Eijkelkamp Soil Water P O Box 4 6987 ZG Giesbeek the Netherlands T 31 313 880 200 E info eijkelkamp com I www eijkelkamp com 2017 05 Meet the difference User manual ...

Страница 2: ...the MP 1 Redi Flo2 pump to the converter 9 8 Start up and operation 9 8 1 Start up 9 8 1 1 Speed control 9 8 2 Operation 10 8 2 1 Setting of pump performance 10 8 2 2 Minimum flow 10 8 2 3 After use 10 8 3 Performance curves MP 1 Redi Flo2 pump 10 9 Maintenance and service 11 9 1 Maintenance 11 9 2 Service 11 10 Dismantling and assembly 12 10 1Description and overview of the MP 1 Redi Flo2 samplin...

Страница 3: ...le converter in the 25 to 400 Hz frequency range At 400 Hz the pump provides a flow rate of 1 m3 h at 74 metres head The pump must always be powered via the converter See fig 1 Pump and converter motor form a complete unit that can easily be dismantled for cleaning and servicing The Teflon power cable is available in different lengths 2 1 Applications The Grundfos MP 1 Redi Flo2 pump is designed f...

Страница 4: ...tor protection Built in thermal switch Water temperature 0 C to 35 C Discharge port Rp 3 4 Continuous operation Maximum 500 hours Net weight 2 5 kg Frequency converters Supply voltage 1 x 200 240 V 10 50 60 Hz Minimum generator size With voltage control 3 0 kVA suitable for non linear loads minimal value 4 5 kVA suitable for non linear loads recommended value 7 5 kVA not suitable for non linear lo...

Страница 5: ...y equipment must be used 3 1 3 Warranty Pumps installed in accordance with these instructions and accepted codes of good practice are covered by the warranty Any constructional change of the pumping system will invalidate the warranty Eijkelkamp Soil Water cannot be held responsible for possible consequential damage 3 1 4 Electrical connection When lowering pulling out the pump take care not to da...

Страница 6: ...riate If a valve has been installed anyway make sure that the pump is only operated against a closed valve for a very short period Otherwise the heat generated will cause the pump to stop If a non return valve is installed in the discharge pipe it must be installed at least 0 5 metres above the pump This is necessary to ensure that the air in the pump is compressed so much that the pump contains w...

Страница 7: ...d hoses are used a stainless steel straining wire is required for lowering and lifting the pump Secure the straining wire to the pump with a wire holder See fig 6 5 6 Lowering the pump Lower the pump into the borehole taking care not to damage the motor cable Do not lower or lift the pump by the motor cable 5 7 Installation depth During operation the pump and motor must be completely submerged to ...

Страница 8: ...746 and for use with the Redi Flo2 converter art no 122747 pump The rest of the functions are blocked by a password and can only be changed by Eijkelkamp That is why only 3 buttons are used to operate the MP 1 Redi Flo2 pump Switch 1 to start the convertor after connecting it to the power supply switch turns hard Switch 2 to set the direction of rotation to Forward FWD Function REW is disabled by ...

Страница 9: ... converter unless the electricity supply to the converter has been switched off 8 Start up and operation 8 1 Start up Switch on the electricity supply when the pump has been installed and connected to the converter Turn switch 1 to ON to start the converter The display shows StoP see fig 8b Turn switch 2 to FWD The display shows H 00 see fig 8c 8 1 1 Speed control Turn switch 3 to in or decrease t...

Страница 10: ...ver be set so low that it gives no water If the flow rate suddenly falls the reason might be that the pump is pumping more water than the borehole can yield The pump performance must immediately be reduced or the pump must be stopped to avoid damage to the pump 8 2 3 After use After use switch off the electricity supply to the converter before the motor cable is disconnected from the converter 8 3...

Страница 11: ...1 is available This kit includes wear parts for two pumps i e 4 washers pos 285 and 4 seals pos 207 See fig 10 The rinsing water from the decontamination and the motor liquid must be collected and disposed of in accordance with local regulations 9 2 Service The MP 1 Redi Flo2 pump is specially designed for the purging and sampling of contaminated and or toxic groundwater As a precaution Eijkelkamp...

Страница 12: ...232 Guide vanes 285 Washer A Pump with motor B Converter When servicing the MP 1 Redi Flo2 sampling pump note that the pumped liquid is often unknown Therefore the necessary precautionary measures must be taken in accordance with local regulations All work on the electric parts of the MP 1 Redi Flo2 sampling pump system must be carried out by a qualified service engineer If the motor motor cable c...

Страница 13: ...f the suction interconnector on the motor pos 1 6 Pull the pump housing and the wear parts including impellers pos 200 off the motor shaft Push the wear parts including impellers out of the pump housing from the discharge side 7 Dismantle the wear parts including impellers pos 200 8 Clean the holes in the suction interconnector 9 Clean and check all parts See section 10 3 Checking of components Fo...

Страница 14: ...uide vanes pos 232 to the intermediate ring 6 Repeat the procedure with seal intermediate ring impeller washer and guide vanes 7 Push the pump housing pos 201a over the wear parts including impellers pos 200 and screw it on the suction interconnector on the motor pos 1 See fig 12 8 Position the cable along the pump housing in the recess 9 Push the strainer pos 215 over the pump housing and press i...

Страница 15: ...om entry and top exit vents are not blocked or obstructed U t 09 Under temperature Trip occurs when ambient temperature is less than 10 C Temperature must be raised over 10 C in order to start the drive P dEF 10 Factory Default parameters loaded E tr iP 11 External trip E trip requested on digital input 3 Normally closed contact has opened for some reason If motor thermistor is connected check if ...

Страница 16: ...ms loss trip Check the incoming CAN connection cable Check that cyclic communications take place within the timeout limit set in P 36 Index 3 See separate manual of the converter 12 Disposal This product or parts of it must be disposed of in an environmentally sound way 1 Use the public or private waste collection service 2 If this is not possible contact the nearest Eijkelkamp Soil Water company ...

Страница 17: ...ews pos 222 and 222a Pull the suction interconnector pos 214 off the motor Slacken and remove the screws pos 20b holding the motor cable Pull the motor cable off the motor Screw positions 20d and 20e out of the motor using a small screwdriver and precision electronic pliers Before fitting the motor cable clean the holes in the motor Pull positions 20b 20d and 20e on the three leads phases of the m...

Страница 18: ...the direction of rotation see 3 2 Checking of direction of rotation 3 Shortening of motor cable Motor cables with a common plastic sheath cannot be repaired or shortened See fig 3 Motor cables with a plastic sheath for each lead new type of cable can be repaired or shortened See fig 4 Cut the cable new type separate and strip the leads See fig 5 Cable to motor L 72 mm L1 4 mm Cable to frequency co...

Страница 19: ...tor Fit the fittings and the hose to the pump The pump is now reassembled and can be tested Fig 7 Fit plug pins Fig 8 Fixing the plug pin Fig 9 Checking direction of rotation Disclaimer Nothing from this document may be copied and or made public by means of printing photocopy microfilm or in any other way without the prior written approval of the publisher Technical data can change without prior n...

Отзывы: