The pump must be installed with the motor shaft
positioned horizontally. Under no circumstances should
the pump be installed with the shaft vertical or where
the shaft falls below the horizontal plane (Fig.4C).
5.
Installation Requirements
•
Thoroughly clean and flush the system prior to
pump installation
•
Ensure that water does not enter the terminal box
during the installation process.
•
DO NOT START THE PUMP UNTIL THE
SYSTEM HAS BEEN FILLED AND CHECKED
FOR LEAKS.
•
Do not use the pump to vent the system.
•
Never operate the pump dry. The bearings
require water lubrication and will be damaged
otherwise.
•
Fill system with water. This will result in immedi-
ate lubrication of the bearings.
•
Operate the pump for 5 minutes, when control
installation is complete, to purge remaining air
from the bearing chamber. This is especially
important when installing the pump during the off-
season.
Recommended
Optional
DO NOT
Mount Motor Shaft
in Vertical Position
Figure 4C
6.
Mounting Control System
Provisions for a 115 V grounded outlet within 6 feet of
the pump mounting location, should be made.
All electrical work should be performed by a
qualified electrician in accordance with the latest