English (GB)
18
Fig. 11
Example of drain plugs
1. After draining the pump during long shutdown periods under
freezing conditions, blow out all liquid in passages and air
pockets using compressed air. You can prevent freezing of
pumped liquid by filling the pump with antifreeze solution.
2. Rotate the shaft by hand monthly to coat the bearings with
lubricant and delay oxidation and corrosion.
3. Where applicable, follow the motor manufacturer's storage
recommendations.
7. Identification
7.1 Nameplate
Fig. 12
Nameplate of LS pump
CAUTION
Hot or cold surface
Minor or moderate personal injury
- Make sure that the escaping water does not cause
injury to persons or damage to the motor or other
components.
- In hot-water installations, pay special attention to
the risk of injury caused by scalding hot water.
- In cold-liquid installations, pay special attention to
the risk of injury caused by cold liquids and cold
surfaces.
T
M
04
03
78
06
08
WARNING
Harm to health
Death or serious personal injury
- Do not use antifreeze solution if you use the pump
for public or potable-water supply.
Do not tighten the vent screw or refit the drain plug
until the pump is to be used again.
Drain plug, inlet port
Drain plug, pump
housing and outlet port
TM
07
21
66
13
19
Pos.
Description
1
Type designation
2
Product number
3
Place of production
4
Production year and week
5
Serial number
6
Maximum pressure and temperature
7
Rated flow rate (duty-point flow rate)
8
Head at rated flow rate (duty-point head)
9
Speed
10
Country of production
11
Reference to LS installation and operating instructions
for bearing lubrication
12
Liquid temperature rating, only for WRAS-approved
pumps
13
Hydraulic pump efficiency at optimum efficiency point
99476910
R e f e r L S I / O f o r l u b r i c a t i o n i n s t r u c t i o n
ȘS
%
D K - 8 8 5 0 B j e r r i n g b r o , D e n m a r k
LS100-80-242E/235 1F2DS BBQE 1 11/4
99281199 P1 1832 0001
16/100
0DGH
in
;;;;
1755
73.9
80
27
WRAS23C
7\SH
Model
SW
n
Q
H
m
3
/h
min
-1
bar/°Cmax
1 2 3 4 5
7
6
8
9
12 13
10
11
Содержание LS 100-80-241
Страница 1: ...LS Service instructions GRUNDFOS INSTRUCTIONS ...
Страница 2: ...2 ...
Страница 22: ...English GB 22 9 Sectional drawings 9 1 LS with sleeve construction type 1 TM03 9952 4707 ...
Страница 29: ...English GB 29 10 2 3 Construction type 3 Fig 17 Construction type 3 LS 200 150 483 X5 TM03 9947 4317 ...
Страница 30: ...English GB 30 Fig 18 Construction type 3 LS 100 80 241 XE TM03 9951 4317 ...
Страница 34: ...English GB 34 Fig 25 Construction type 4 LS 300 200 489 LS 350 250 508 TM03 9942 4317 ...
Страница 44: ...44 ...
Страница 45: ...45 ...
Страница 46: ...46 ...