background image

13

Eng

lish (US

)

chapter discard.fm  Page 13  Tuesday, June 7, 2011  9:29 PM

LIMITED WARRANTY

Products  manufactured  by  GRUNDFOS  PUMPS  CORPORATION  (GRUNDFOS)    are  warranted 
to  the  original  user  only  to  be  free  of  defects  in  material    and  workmanship  for  a  period  of 
24  months  from  date  of  installation,  but  not  more  than  30  months  from  date  of  manufac-
ture.  GRUNDFOS’  liability  under  this  warranty  shall  be  limited  to  repairing  or  replacing  at
GRUNDFOS’  option,  without  charge,  F.O.B.  GRUNDFOS’  factory  or  authorized  service  sta-
tion, any product of GRUNDFOS’ manufacture. GRUNDFOS will not be liable for any costs of 
removal, installation, transportation, or any other charges which may arise in connection with 
a warranty claim. Products which are sold but not manufactured by GRUNDFOS are subject to 
the warranty provided by the manufacturer of said products and not by GRUNDFOS’ warranty. 
GRUNDFOS will not be liable for damage or wear to products caused by abnormal operating 
conditions, accident, abuse, misuse, unauthorized alteration or  repair, or if the product was 
not installed in accordance with GRUNDFOS’ printed installation and operating instructions.

To  obtain  service  under  this  warranty,  the  defective  product  must  be  returned  to  the
distributor  or  dealer  of  GRUNDFOS’  products  from  which  it  was  purchased  together  with 
proof of purchase and installation date, failure date, and supporting installation data. Unless
otherwise provided, the distributor or dealer will contact GRUNDFOS or an authorized service 
station for instructions. Any defective product to be returned to GRUNDFOS or a service station 
must be sent freight prepaid; documentation supporting the warranty claim and/or a Return 
Material Authorization must be included if so instructed.

GRUNDFOS  WILL  NOT  BE  LIABLE  FOR  ANY  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES, 
LOSSES,  OR  EXPENSES  ARISING  FROM  INSTALLATION,  USE,  OR  ANY  OTHER  CAUSES.  THERE 
ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED 
TO ABOVE.

Some  jurisdictions  do  not  allow  the  exclusion  or  limitation  of  incidental  or  consequential
damages  and  some  jurisdictions  do  not  allow  limitations  on  how  long  implied  warranties 
may last. Therefore, the above limitations or exclusions may not apply to you. This warranty 
gives you specific legal rights and you may also have other rights which vary from jurisdiction
to jurisdiction.

Содержание HS 100 0505

Страница 1: ...GRUNDFOS INSTRUCTIONS HS Horizontal single stage end suction pumps Installation and operating instructions discard fm Page 1 Tuesday June 7 2011 9 24 PM...

Страница 2: ...Do not destroy packing materials until the shipment is inspected and the claim is settled The position of the coupling that connects the pump shaft to the motor shaft is set at factory specifications...

Страница 3: ...kets to form Discharge piping It is suggested that a check valve and isolation valve be installed in the discharge pipe Pipe valves and fittings should be at least the same diameter as the discharge p...

Страница 4: ...e motors should remain mounted with the cooling vents positioned downward especially where there is the possibility that liquid might splash onto the pump from above i e rain FIGURE 3 Motor mounting p...

Страница 5: ...t be purged while the system is being filled Replace the drain vent plug and securely tighten Connect and or seal the discharge piping Check motor rotation 1 Make sure power is off 2 Check to make sur...

Страница 6: ...Over greasing will cause increased bearing heat and can result in bearing motor failure Do not mix petroleum grease and silicon grease in motor bear ings Bearing grease will lose its lubricating abil...

Страница 7: ...y torque 15 to 20 ft lbs 4 Using the appropriate edge of impeller spacing tool SV00201 see Table C position the impeller at the cor rect axial location and tighten allen shaft set screw s into the mot...

Страница 8: ...AND SPARE PARTS PRICE LISTS FOR A COMPLETE LISTING OF KIT COMPONENTS Part Lists and Diagrams Model B HS 100 0505 to HS 125 1515 HS100 0305 to HS125 1520 Motor Stool 56C Frame Pump Base 3 4 Type 21 Joh...

Страница 9: ...0 2020 to HS 150 3030 Motor Stool 182TC 184TC 1 Type 21 John Crane Seal Stub Shaft 416ss Impeller HS 150 5050 Impeller HS 150 7575 Pump Volute Volute Gasket 5 16 18 x 3 8 Shaft Set Screw Woodruff Key...

Страница 10: ...it means If the amp draw exceeds the listed serv ice factor amps SFA or if the current imbalance is greater than 5 between each leg on three phase units check the following 1 Burned contacts on the mo...

Страница 11: ...start pump gradually close the dis charge valve and read pressure at shut off Disassemble and inspect pump passageways Fault A Pump does not run B Pump runs but at reduced capacity or does not deliver...

Страница 12: ...ecord values Check proper wiring and loose terminals Turn off power and manually rotate pump shaft Turn off the power and discharge the capacitor Check with ohm meter R x 100K Use a thermometer to che...

Страница 13: ...erating instructions To obtain service under this warranty the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of p...

Страница 14: ...English US 14 chapter discard fm Page 14 Tuesday June 7 2011 9 29 PM This page intentionally left blank...

Страница 15: ...Kansas 66061 Phone 1 913 227 3400 Telefax 1 913 227 3500 Canada GRUNDFOS Canada Inc 2941 Brighton Road Oakville Ontario L6H 6C9 Phone 1 905 829 9533 Telefax 1 905 829 9512 M xico Bombas GRUNDFOS de M...

Страница 16: ...the essence The name Grundfos the Grundfos logo and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A S or Grundfos A S Denmark All rights reserved worldwide L EP...

Отзывы: