10. Technical data
10.1 Operating conditions
10.1.1 Operating mode
The pumps are designed for intermittent operation
(S3). When completely submerged in the pumped
liquid, the pumps can also operate continuously
(S1).
10.1.2 Installation depth
Maximum 10 m below liquid level.
10.1.3 Operating pressure
Maximum 6 bar.
10.1.4 Number of starts per hour
Maximum 30.
10.1.5 pH value
Pumps in permanent installations can be used for
pumping liquids with a pH value between 4 and 10.
10.1.6 Liquid temperature
0-40 °C.
For short periods of maximum 10 minutes, a
temperature of up to 60 °C is allowed. This applies
for standard versions only.
10.1.7 Density of pumped liquid
When pumping liquids with a density and/or a
kinematic viscosity higher than that of water, use
motors with correspondingly higher outputs.
10.1.8 Sound pressure level
The sound pressure level of the pumps is lower than
the limiting values stated in the EC Council Directive
2006/42/EC relating to machinery.
10.2 Electrical data
10.2.1 Power supply
•
1 x 230 V - 10 %/+ 6 %, 50 Hz
•
3 x 400 V - 10 %/+ 10 %, 50 Hz
10.2.2 Enclosure class
IP68, according to IEC 60529.
10.2.3 Insulation class
F (155 °C).
10.2.4 Pump curves
Pump curves are available via www.grundfos.com.
The curves are to be considered as a guide. They
must not be used as guarantee curves.
Test curves for the supplied pump are available on
request.
10.3 Dimensions and weights
10.3.1 Dimensions
See figs
10.3.2 Weights
Weights do not include accessories.
11. Disposing of the product
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
The crossed-out wheelie bin symbol on
a product means that it must be
disposed of separately from household
waste. When a product marked with this
symbol reaches its end of life, take it to a
collection point designated by the local
waste disposal authorities. The separate collection
and recycling of such products will help protect the
environment and human health.
See also end-of-life information at
www.grundfos.com/product-recycling.
Explosion-proof pumps must never pump
liquids at a temperature higher than 40 °C.
Power [kW]
Weight [kg]
DP 0.9 - 1.5
39
DP 2.6
68
EF 0.6 - 1.5
39
Содержание DP AUTOADAPT Series
Страница 28: ...Appendix 28 Fig 4 Exploded view of DP 10 50 pump TM06 5879 0316...
Страница 29: ...Appendix 29 Fig 5 Exploded view of DP 10 65 pump TM06 5900 0316...
Страница 30: ...Appendix 30 Fig 6 Exploded view of EF 30 50 pump TM06 5913 0316...
Страница 46: ...Appendix 46 188a 188b 188c 189 190 193 193a 194 198 199 285 285a 285b 287 287a 287b 287c 532 Pos AR...
Страница 47: ...47...