2.1 Definitions 

Correct dosing stroke:

 A pulse from the dosing 

monitor corresponds to the internal stroke signal 
within acceptable time.

Incorrect dosing stroke: 

There is no pulse from the 

dosing monitor corresponding to the internal stroke 
signal within the acceptable time (the pump is not 
pumping).

2.2 Logic 

If two incorrect dosing strokes are performed, the 
pump will continue operating, but it will change over 
to alarm mode, like in the case of "low level". The red 
indicator light will be on and the alarm output, if any, 
will be activated (variant AR). 

For each correct stroke the counter is reset and the 
alarm output, if any, is deactivated.

2.3 Operation with vent valve

Fig. 2 

It is possible to achieve a self-acting solution for liq-
uids which may cause gas accumulation by using an 
automatic vent valve together with the dosing moni-
tor and an alarm output (control variant AR). The 
alarm output can thus activate the vent valve, which 
automatically vents the gas accumulated in the dos-
ing head. When the dosing head has been vented, 
the pump will start pumping again, the alarm output 
will be deactivated and the vent valve will close.

TM

02

 40

99

 48

01

N

F

NO C

N

F

Содержание Dosing monitor

Страница 1: ...Dosing monitor GRUNDFOS INSTRUCTIONS Installation and operating instructions...

Страница 2: ...2...

Страница 3: ...i n y funcionamiento 16 19 Installatie en bedieningsinstructies 22 Monterings och driftsinstruktion 25 Asennus ja k ytt ohjeet 28 Monterings og driftsinstruktion 31 Instrukcja monta u i eksploatacji 3...

Страница 4: ...as in the dosing head When used together with a DME pump the monitor will only operate if it is mounted on the suction side of the pump When used together with a DMS pump the monitor will operate if i...

Страница 5: ...t will be on and the alarm output if any will be activated variant AR For each correct stroke the counter is reset and the alarm output if any is deactivated 2 3 Operation with vent valve Fig 2 It is...

Страница 6: ...ose the bypass valve and prime the floater channel 8 Open the bypass valve and check that the pump is in alarm mode the red indicator light is on 9 Close the bypass valve gradually and adjust the cont...

Страница 7: ...61...

Страница 8: ...62...

Страница 9: ...efax 81 53 484 1014 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia D...

Страница 10: ...www grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96470727 1105 216 Repl 96470727 0303 96488980 0303...

Отзывы: