English (GB)
9
3.4.2 Suction heights for media with maximum permissible
viscosity
Applies to:
• Newtonian liquids
• non-degassing and non-abrasive media
• temperature of 20 °C.
3.5 Ambient and operating conditions
• Permissible ambient temperature: 0 °C to +40 °C.
• Permissible storage temperature: -20 °C to +50 °C.
• Permissible air humidity: max. relative humidity:
70 % at 40 °C, 90 % at 35 °C.
• Sound pressure level: ± 55 dB(A), testing according to
DIN 45635-01-KL3.
• Minimum counterpressure: 1 bar at the pump discharge valve.
Pay attention to the pressure losses along the way to the
injection point inclusively.
Pumps with AR control unit only
Maximum permissible mains impedance: 0.084 + j 0.084
Ω
(testing according to EN 61000-3-11).
3.6 Dosing medium
The dosing medium must have the following basic characteristics:
• liquid
• non-abrasive
• non-flammable.
3.6.1 Permissible media temperature
* For SIP/CIP applications: A temperature of 145 °C at a
counterpressure of max. 2 bar is permitted for a short period
(15 minutes).
3.7 Electrical data
3.7.1 Enclosure class
The enclosure class depends on the motor variant selected, see
motor nameplate.
The specified enclosure class can only be ensured if the power
supply cable is connected with the same degree of protection.
Pumps with electronics: The enclosure class is only met if the
sockets are protected! The data regarding the enclosure class
applies to pumps with correctly inserted plugs or screwed-on
caps.
3.7.2 Motor
Version: see motor and pump nameplates.
3.8 AR control unit
Functions of pumps with electronics:
• "Continuous operation" button for function test and dosing
head deaeration
• memory function (stores a maximum of 65000 pulses)
• two-stage tank-empty signal (e.g. via Grundfos tank empty
sensor)
• stroke signal/pre-empty signal (adjustable), e.g. as a feedback
to the control room
• dosing controller function (only with sensor - optional)
• diaphragm leakage detection (only with sensor - optional)
• access-code-protected settings
• remote on/off
• Hall sensor
• operating hours counter
• motor monitoring.
Operating modes:
• manual
Stroke frequency: manually adjustable between zero and
maximum
• contact signal control
Multiplier (1:n) and divisor (n:1)
• current signal control 0-20 mA / 4-20 mA
Adjustment of stroke frequency proportional to the current
signal.
Weighting of current input.
Pump type
Maximum viscosity
[mPa s]
Intake height
[mWC]
DMX 4-10
400
1
DMX 7-10
400
1
DMX 9-10
200
1
DMX 12-10
200
1
DMX 17-4
200
1 mWC flooded suction
DMX 25-3
200
1 mWC flooded suction
DMX 7.2-16
400
1
DMX 8-10
400
1
DMX 14-10
400
1
DMX 18-10
200
1
DMX 26-10
200
1 mWC flooded suction
DMX 39-4
100
1
DMX 60-3
100
1
DMX 13.7-16
200
1
DMX 16-10
200
1
DMX 27-10
200
1
DMX 35-10
100
1
DMX 50-10
100
1
DMX 75-4
100
1 mWC flooded suction
DMX 115-3
100
1 mWC flooded suction
Caution
The installation site must be under cover!
Ensure that the enclosure class of motor and
pump are not affected by the atmospheric
conditions.
Pumps with electronics are only suitable for
indoor use! Do not install outdoors!
Warning
Risk of hot surfaces!
Pumps with AC motors may become hot.
Allow a minimum space of 100 mm above the fan
cover!
Caution
In the event of questions regarding the material
resistance and suitability of the pump for specific
dosing media, please contact Grundfos.
Dosing head
material
Temperature range
p < 10 bar
p < 16 bar
PVC
0 °C to 40 °C
0 °C to 20 °C
Stainless steel*
-10 °C to 70 °C
-10 °C to 70 °C
PP
0 °C to 40 °C
-
PVDF
-10 °C to 60 °C
-10 °C to 20 °C
70 °C at 9 bar
Caution
Observe the freezing and boiling points of the
dosing medium!