English (GB)
14
Fig. 6
DMH 257
5.1.1 Combined overpressure and degassing valve
The combined overpressure and degassing valve (M) opens if
there is an excessive pressure build-up in the dosing system and
provokes the constant degassing of the hydraulic medium.
5.1.2 Diaphragm protection system AMS
The diaphragm protection system AMS (9p) has a keypad, which
is connected to the dosing diaphragm. The dosing diaphragm
oscillates freely in the dosing head and cannot be overstretched
due to a fault in the dosing system since the diaphragm protection
valve closes if such a fault occurs.
TM
03
6
4
52
45
06
1p
F
L
M
3b
3a
9p
3p
2p
5p
6p
2
Q
7p
Pos.
Components
1p
Motor
2p
Worm gearing
3p
Eccentric
4p
Recuperating spring (not with drive size 3)
5p
Sliding plug
6p
Piston
7p
Crank
M
Combined overpressure and degassing valve
E
Degassing valve
9p
Diaphragm protection system (AMS)
Q
Dosing diaphragm
2
Dosing head
3a
Suction valve
3b
Discharge valve
L
Stroke-length adjustment knob
F
Oil-filling screw with dipstick