English (GB)
12
4.4.3 Dosing control (Flow Monitor)
The pressure sensor (Flow Monitor pump option) is used as a
dosing controller and to monitor the pressure for the whole power
ranges.
The Flow Monitor for dosing control consists of a pressure sensor
integrated in the dosing head.
The pressure sensor is available as Flow Monitor pump option.
The pressure sensor is fitted to the pump on delivery. Upgrades
are not possible.
4.4.4 Flow compensation
The flow compensation is a function to keep the dosing flow
constant with changing system pressure. Pressure changes are
detected by the pressure sensor and the motor speed is adjusted
accordingly.
To use this function, pressure control or dosing control (Flow
Monitor) has to be activated in the electronics.
4.5 Dimensional sketches
Fig. 4
DDI 222
Dimensions for DDI 222
Note
Pressure control is primarily used to protect the
pump. This function is not a substitute for the
overflow valve.
Note
When dosing media with a viscosity similar to water,
the pump needs not to be calibrated, as the pump
already responds to the possible change of the
system pressure.
When dosing media with a viscosity different from
water or after a software update, the pump has to be
calibrated.
TM
03 66
63 450
6
A4
A3
H2
D1
C4
C1
207
172.5
16.5
Ø7
10
7
61.5
105
123
B3
B4
230
175
(159)
A5
H3
MLS
DS
MBS: Diaphragm leakage sensor (optional)
DS: Pressure sensor (Flow Monitor pump option)
A3
[mm]
A4
[mm]
A5
[mm]
B3
[mm]
B4
[mm]
C1
[mm]
C4
[mm]
D1
H2
[mm]
H3
[mm]
DDI 60-10
283
338
306
137
-
58
37
R 5/8
252
153
DDI 150-4
315
372
350
137
139
90
39
R 1 1/4
265
179
DDI 60-10 / HV
295
350
328
137
-
68
38
R 1 1/4
246
143
DDI 150-4 / HV
315
372
350
137
139
90
39
R 1 1/4
265
179
Содержание DDI 150-4
Страница 2: ...2 ...
Страница 630: ...630 ...