5.4.1 Installation tips
• For non-degassing media with a viscosity similar to water, the
pump can be mounted on the tank (observe the permissible
suction lift).
• Flooded suction preferred.
• For media with a tendency to sedimentation, install the suction
line with filter (15i) so that the suction valve remains a few
millimetres above the possible level of sedimentation.
Fig. 7
Tank installation
With open outflow of the dosing medium or low
counter-pressure
A positive pressure difference of at least 1 bar must be ensured
between the counter-pressure at the injection point and the
pressure of the dosing medium at the pump suction valve.
• If this cannot be ensured, install a pressure-loading valve (7i)
immediately before the outlet or the injection unit.
Fig. 8
Installation with pressure-loading valve
• To avoid the siphon effect, install a pressure-loading valve (7i)
in the discharge line and, if necessary, a solenoid valve (14i) in
the suction line.
Fig. 9
Installation to avoid the siphon effect
• To protect the dosing pump against excessive pressure
build-up, install a relief valve (6i) in the discharge line.
• For degassing media:
– Flooded suction.
– Install a filter (15i) in the suction line to prevent the valves
being contaminated.
Fig. 10
Installation with relief valve and filter
• For line lengths above 1 metre a suction pulsation damper (4i)
may be required, depending on the flow rate.
Fig. 11
Installation with suction pulsation damper
• For damper and line lengths above 3 metres and for flexible
pipework and line lengths above 5 metres, a pulsation damper
(8i) must be used to protect the system.
Fig. 12
Installation with pulsation damper
T
M
03
66
66
45
06
TM
03
66
67
45
06
TM
03
66
68
45
06
13i
6i
10i
p
15i
7i
>
p _ 1bar
p
1 bar
7i
14i
1
2
>
p -p _ 1bar
p
1
p
2
p
2
- p
1
1 bar
TM
03
66
69
45
06
T
M
03
66
7
0
45
0
6
T
M
03
66
71
45
06
15i
10i
6i
p
4i
8i
Содержание DDI 150-4
Страница 2: ...2 ...
Страница 630: ...630 ...