background image

English (GB)

4

8. Startup

1. Open the isolating valve on the suction side of the pump.
2. Close the isolating valve on the discharge side of the pump.
3. Loosen the vent screw in the pump head.
4. Slowly fill the pump with liquid.
5. Tighten the vent screw when the pump has been completely 

filled with liquid.

6. Slowly open the isolating valve on the discharge side of the 

pump.

7. Start the pump.
8. Check the direction of rotation by means of the motor fan and 

the label on top of the fan cover.

9. After startup, the pump should be vented again.

Slowly loosen the vent screw in the pump head.

10. When liquid runs out, tighten the vent screw securely.

9. Maintenance

The pump requires no maintenance if is has been installed 
according to the instructions.

10. Fault finding

See the installation and operating instructions of CR, CRI, CRN.

11. Service

If Grundfos is requested to service the pump, Grundfos must be 
contacted with details about the pumped liquid, etc. before the 
pump is returned for service. Otherwise, Grundfos can refuse to 
accept the pump for service.
Possible costs of returning the pump are paid by the customer.

11.1 Other documentation

Service and other documentation for CR pumps can be found at 
Grundfos Product Center.
If you have any questions, please contact the nearest Grundfos 
company or service workshop.

12. Disposal

This product or parts of it must be disposed of in an 
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company 

or service workshop.

The crossed-out wheelie bin symbol on a product 
means that it must be disposed of separately from 
household waste. When a product marked with this 
symbol reaches its end of life, take it to a collection 
point designated by the local waste disposal 

authorities. The separate collection and recycling of such 
products will help protect the environment and human health.

Note

Do not start the pump until it has been filled with 
liquid and vented.

Warning
Pay attention to the direction of the vent hole to 
ensure that the escaping liquid does not cause injury 
to persons or damage to the motor or other 
components.

Warning
The pump contains powerful magnets that may pose 
a risk of personal injury when servicing the pump. 
The pump should therefore only be dismantled and 
assembled by authorised personnel.

Содержание CRN MAGdrive Series

Страница 1: ...CRN MAGdrive Installation and operating instructions GRUNDFOS INSTRUCTIONS ...

Страница 2: ...n personal injury Caution If these safety instructions are not observed it may result in malfunction or damage to the equipment Note Notes or instructions that make the job easier and ensure safe operation Warning Persons with pacemaker or other magnet sensitive medical devices must not handle this pump They must keep a distance of at least 1 metre from the MAGdrive as there is a risk of influence...

Страница 3: ...with instantaneous release when the maximum setting of the current is reached If a soft starter or a frequency converter is used it must also be with instantaneous release In order to ensure the optimum protection of the MAGdrive motor the motor protection should be set in accordance with the following guidelines 1 Set the overload protection to the rated full load current I1 1 of the motor 2 Star...

Страница 4: ...ning the pump are paid by the customer 11 1 Other documentation Service and other documentation for CR pumps can be found at Grundfos Product Center If you have any questions please contact the nearest Grundfos company or service workshop 12 Disposal This product or parts of it must be disposed of in an environmentally sound way 1 Use the public or private waste collection service 2 If this is not...

Страница 5: ...UNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava ielā 60 LV 1035 Rīga Tālr 371 714 9640 7 149 641 Fakss 371 914 9646 Lithuania GRUNDFOS Pumps UAB Smolensko g 6 LT 03201 Vilnius Tel 370 52 395 430 Fax 370 52 395 431 Malaysia GRUNDFOS Pumps ...

Страница 6: ...isplayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 Grundfos Holding A S all rights reserved www grundfos com ...

Отзывы: