4. Technical data

Minimum flow rate

The pump 

must never

 run without flow. The curve below shows 

the minimum flow rate as a percentage of the rated flow rate in 
relation to the liquid temperature.

Fig. 2

Minimum flow rate

5. Type key

See also the installation and operating instructions of CR, CRI, 
CRN.

6. Mechanical installation

Before installation, check that the pump and its components are 
as ordered and that no visible parts have been damaged.

6.1 Installation of pump

The pump must be installed and put into operation as described 
in the installation and operating instructions of CR, CRI, CRN.
We recommend to protect CRN MAGdrive pumps against dry 
running by installing a flow switch, pressure switch or a LiqTec 
sensor close to the pump. The delay of the dry-running protection 
must be maximum 15 seconds.

6.2 Connection of sensor

A pressure sensor or a Grundfos LiqTec dry-running protection 
unit can be fitted in the threaded hole in the pump head.

7. Electrical connection

The pump must be installed as described in the installation and 
operating instructions of CR, CRI, CRN.
Pumps with 2-pole motors of 18.5 and 22 kW and 4-pole motors 
as from 1.1 kW must be started via a soft starter.

7.1 Motor protection

As a minimum, the motor must be connected to an effective 
electronic motor protection with instantaneous release when the 
maximum setting of the current is reached. If a soft starter or a 
frequency converter is used it must also be with instantaneous 
release.
In order to ensure the optimum protection of the MAGdrive motor, 
the motor protection should be set in accordance with the 
following guidelines:
1. Set the overload protection to the rated full-load current (I

1/1

of the motor.

2. Start the pump and let it run for half an hour at the required 

duty point.

3. Measure the motor current. If not possible, slowly grade down 

the scale indicator until the motor trip point is reached. 

4. The setting of the motor protection must be 5 % higher than 

this value.
The highest permissible setting of the motor protection is the 
rated full load current (I

1/1

) of the motor.

Liquid temperature:

-30 to 120 °C.

Maximum system pressure:

25 bar.

Viscosity:

0.15 to 300 cSt (mm

2

/s).

TM

02

 82

90

 49

03

Example

CRN

5

-13

-M

-F -G -E

Type range
Rated flow rate in m

3

/h

Number of impellers
Code for pump version
M: CRN pump with magnetic drive
Code for pipe connection
CA: FlexiClamp
CX: TriClamp
F:

DIN flange

G: ANSI flange
J:

JIS flange

P:

PJE coupling

Code for materials
G: Wetted parts EN 1.4401/AISI 316
Code for rubber parts of pump
E: EPDM
F: FXM (Fluoraz

®

)

K: FFKM (Kalrez

®

)

N: CR (Neoprene)
V: FKM (Viton

®

)

40

50

60

70

80

90 100 110 120 t [°C]

0

10

20

30

Qmin

[%]

Warning
Installation and operation must comply with local 
regulations and accepted codes of good practice.

Description

Dimension

Threaded connection:

RG 1/2

Max. installation length, sensor:

20 mm

Содержание CRN MAGdrive Series

Страница 1: ...CRN MAGdrive Installation and operating instructions GRUNDFOS INSTRUCTIONS ...

Страница 2: ...n personal injury Caution If these safety instructions are not observed it may result in malfunction or damage to the equipment Note Notes or instructions that make the job easier and ensure safe operation Warning Persons with pacemaker or other magnet sensitive medical devices must not handle this pump They must keep a distance of at least 1 metre from the MAGdrive as there is a risk of influence...

Страница 3: ...with instantaneous release when the maximum setting of the current is reached If a soft starter or a frequency converter is used it must also be with instantaneous release In order to ensure the optimum protection of the MAGdrive motor the motor protection should be set in accordance with the following guidelines 1 Set the overload protection to the rated full load current I1 1 of the motor 2 Star...

Страница 4: ...ning the pump are paid by the customer 11 1 Other documentation Service and other documentation for CR pumps can be found at Grundfos Product Center If you have any questions please contact the nearest Grundfos company or service workshop 12 Disposal This product or parts of it must be disposed of in an environmentally sound way 1 Use the public or private waste collection service 2 If this is not...

Страница 5: ...UNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava ielā 60 LV 1035 Rīga Tālr 371 714 9640 7 149 641 Fakss 371 914 9646 Lithuania GRUNDFOS Pumps UAB Smolensko g 6 LT 03201 Vilnius Tel 370 52 395 430 Fax 370 52 395 431 Malaysia GRUNDFOS Pumps ...

Страница 6: ...isplayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 Grundfos Holding A S all rights reserved www grundfos com ...

Отзывы: