7. Starting up the product
WARNING
Corrosive liquids
Death or serious personal injury
‐
Wear personal protective
equipment.
WARNING
Toxic liquids
Death or serious personal injury
‐
Wear personal protective
equipment.
CAUTION
Hot or cold liquid
Minor or moderate personal injury
‐
Wear personal protective
equipment.
‐
Pay attention to the direction of the
vent hole when you fill the pump
with liquid and vent it.
‐
Make sure that no persons are hurt
by the escaping liquid.
Fill the pump with liquid and vent it
before you start the pump.
Pay attention to the direction of the
vent hole during liquid filling and
venting. Make sure that the escaping
liquid does not cause damage to the
motor or other components.
Vent valve, standard and an optional solution
with hose connection
TM058098
TM051
160
7.1 Startup procedure
1. Close the isolating valve on the outlet side of
the pump and open the isolating valve on the
inlet side.
TM066882
2. Remove the priming plug from the pump head
and slowly fill the pump with liquid. Replace
the priming plug and tighten securely.
TM066883
3. See the correct direction of rotation of the
pump on the motor fan cover.
TM066884
4. Start the pump and check the direction of
rotation.
TM066885
21
English (US)