8.5.2 Start/stop of pump
Stop the pump by pressing
. When the pump is stopped, the
"Stop" text next to the button will illuminate. The pump can also be
stopped by continuously pressing
until none of the light fields
are on.
Start the pump by pressing
or by continuously pressing
until the desired setpoint is indicated.
If the pump has been stopped by pressing
, it can only be
given free to operation by pressing
again.
If the pump has been stopped by pressing
, it can only be
restarted by pressing
.
The pump can also be stopped with the R100, Grundfos GO
Remote, or via a digital input set to "External stop".
8.5.3 Resetting of alarms and warnings
A fault indication can be reset in one of the following ways:
1.
Via the digital input if it has been set to "Alarm resetting".
2.
Briefly press
or
on the pump. This will not change
the setting of the pump. A fault indication cannot be reset by
pressing
or
if the buttons have been locked.
3.
Switch off the power supply until the indicator lights are off.
4.
Switch the external start/stop input off and then on again.
5.
With the R100/Grundfos GO Remote.
8.6 Setting by means of Grundfos GO
8.6.1 Grundfos GO Remote
The product is designed for wireless radio or infrared
communication with Grundfos GO Remote.
Grundfos GO Remote enables you to set functions and gives you
access to status overviews, technical product information, and
current operating parameters.
Use Grundfos GO Remote together with this mobile interface:
•
Grundfos MI 301.
+
1
TM066256
Pos. Description
1
Grundfos MI 301:
Separate module enabling radio or infrared communication.
Use the module together with an Android or iOS-based
smart device via a Bluetooth connection.
8.6.2 Communication
When Grundfos GO Remote initiates communication with the
product, the indicator light in the center of Grundfos Eye flashes
green.
On products fitted with an advanced operating panel, the display
indicates that a wireless device is trying to connect to the product.
Press
OK
on the operating panel to connect the product with
Grundfos GO Remote, or press the
Home
button to reject
connection.
Symbol
Description
Press
OK
on the operating
panel to connect the product
with Grundfos GO Remote.
Setpoint
5.00 bar
Operaring mode
Normal
Actual controlled value
4.90 bar
Control mode
Const. pressure
Status Settings Assist
1
2
3
5
6
7
8
9
Press the
Home
button to reject
connection.
You can choose between these communication types:
•
radio communication
•
infrared communication.
8.6.3 Radio communication
Radio communication can take place at distances up to 98 ft (30
m). The first time Grundfos GO Remote communicates with the
product, you enable communication by pressing the
Radio
communication
button or
OK
on the operating panel.
Later when communication takes place, the product is recognized
by Grundfos GO Remote, and you can select the product from
the
List
menu.
8.6.4 Infrared communication
Infrared communication can take place at distances up to
minimum 6.5 ft (2 m).
When communicating via infrared light, Grundfos GO Remote must
be pointed at the operating panel of the product.