English (GB)
7
3.3 Connecting the outlet hose or pipe
The adapter enables the connection of a hose
matching 3/4" or 1" external pipe thread. Cut the
adapter so that it matches the hose diameter. You
can also connect a pipe directly to the pump.
Fig. 3
Adapter
3.4 Non-return valve
Connect the non-return valve to the SB pump. The
non-return valve has G 1" threads for connection to
the adapter or the pipe.
Fig. 4
Non-return valve
3.5 Pump position
Use the pump in the vertical position as shown in fig.
Fig. 5
Pump position
3.6 Mechanical installation
3.6.1 Lifting the product
Fig. 6
Lifting the pump
3.7 Electrical connection
TM
06
76
45
27
15
TM
0
6
7
646
4
016
T
M
06
76
43
40
1
6
3
/
4
"
1"
15 °
90 °
0 °
Do not lift the product by the power supply
cable. Lift the product by means of a rope.
T
M
06
75
24
40
1
6
DANGER
Electric shock
Death or serious personal injury
- The protective earth of the socket outlet
must be connected to the protective
earth of the pump. The plug must
therefore have the same PE connection
system as that of the socket outlet. If
not, use a suitable adapter.
We recommend that you fit the permanent
installation with a residual-current circuit
breaker, RCCB, with a tripping current less
than 30 mA.
DANGER
Electric shock
Death or serious personal injury
- If the pump is used for cleaning or other
maintenance of swimming pools,
garden ponds or similar places, make
sure that the pump is supplied through a
residual-current circuit breaker, RCCB,
with a tripping current of 30 mA.
DANGER
Electric shock
Death or serious personal injury
- Connect pumps that are delivered
without cable and/or plugs to an
external main switch with a minimum
contact gap of 3 mm in all poles.
SB