Instruction manual 1.0.0 rev1 en  

GROW

BASE  

 

 

7

 

 

Device description 

The digital climate controller 

GROW

BASE

 

 

is the control station for the ambitious indoor gardener. A number of different devices 
and sensors can be connected, which guarantees maximum flexibility. 

 

is similarly able to control standard duct fans as well as  EC fans, offering maximum 
flexibility. 

 

keeps the grow room temperature at the desired value by varying the air flow of the 
fans. 

 

keeps the humidity in the grow room at the designed value by switching a humidifier or 
dehumidifier. 

 

can additionally reduce the humidity in the grow room by increasing the air flow. 

 

can be updated via the USB port. 

 

brings a 24h timer for switching lights, an interval timer with separate settings for day 
and night as well as multiple event timers. 

 

has a battery powered real time clock to keep track of time even if the controller is not 
connected to the mains supply. 

 

can dim compatible lights using a 0-10V/1-10V signal. Ramps for sunrise and sunset can 
be configured. 

 

is equipped with four programmable power sockets. 

 

has a transistor output (MOSFET) that can be used for switching external DC relays or 
contactors. 

 

is able to control the CO

  level in the grow room with a CO

  sensor 

CARB

SENSE

 

connected. 

 

is able to calibrate the connected CO

 sensor. 

 

ensures a constant negative pressure in the grow room, avoiding the escape of odours 
from the grow room. To maintain an accurate negative pressure, a pressure sensor 

PRES

SENSE 

can also be connected. 

 

uses the current sensor values to calculate the values expected in the future. This enables 
the controller to react precociously to changing sensor readings. 

 

is able to regulate the temperature and humidity as precisely as ±0.5°C/±1% RH. * 

 

uses well-tuned PID algorithms for controlling the environmental conditions. 

 

can control the temperature of a heating mat. The temperature can be set to a certain 
value or a temperature relative to the room temperature. (individual for day/night)  

 

is equipped with an easy-to-use multilingual (English, German) menu. Many different 
setups can be achieved, e.g. adjusting the minimum and maximum fan speed separately 
for day and night. It offers a range of information including the current temperature, CO

 

concentration, current humidity, min/max temperature values and humidity, current fan 
speeds and other information regarding the operating condition. 

 

saves the settings permanently to ensure that they remain available after a power 
breakdown or after the controller has been temporarily out of use. 

Содержание GROWBASE

Страница 1: ...winnerstr 46 60388 Frankfurt Germany Mail info growcontrol de Web www growcontrol de Instruction Manual GROWBASE Multifunctional digital climate controller with timer functions and CO control For AC a...

Страница 2: ...observe the relevant information Store this instruction manual and make it accessible to all users Ensure that you include this instruction manual when handing over the device to third parties With k...

Страница 3: ...detail 13 7 1 Info level 13 7 2 Climate 15 7 3 CO2 16 7 4 Ventilation 18 7 5 Timing 21 7 6 Lights 22 7 7 Advanced setup 23 7 8 System setup 23 7 9 Multifunctional Out 26 7 10 Firmware update 26 8 Appe...

Страница 4: ...well as plug connections for their proper condition prior to each use Check the proper status of all parts connected to the device Do not use the device if it is damaged Do not pull on the cables to...

Страница 5: ...of fire if the device is used improperly or these instructions for use are ignored Never use the device near highly flammable substances Operation Warning The device is only intended for the purpose d...

Страница 6: ...to a power socked on the controller It should be connected to a standard power socked that is always on The speed control and switch off is done with the signal from the corresponding RJ45 jack Warni...

Страница 7: ...ors is able to control the CO level in the grow room with a CO sensor CARBSENSE connected is able to calibrate the connected CO sensor ensures a constant negative pressure in the grow room avoiding th...

Страница 8: ...the included screws dowels and drilling template Provided that the sizing of the connected utilities is appropriate and the fresh air temperature is sufficiently low The tolerance is related to the re...

Страница 9: ...0V dimming of lights and Multifunctional Out 5 4 RJ45 jack for exhaust EC fan 5 RJ45 jack for intake EC fan 6 5xRJ45 jack for sensors and PowerExtenders 7 USB A Port for firmware updates 8 11 Programm...

Страница 10: ...nctions according to your requirements 4 Connect the EC fans to the RJ45 jacks labelled intake and exhaust 4 5 using a suitable cable 5 Connect other accessories sensors lights with 0 10 1 10V etc to...

Страница 11: ...ev1 en GROWBASE 11 Menu overview Setup Info 1 Start Climate setup 2 System setup 8 Advanced setup 7 Cancel return home Save return home Save apply Lights setup 6 Timing setup 5 Ventilation setup 4 CO2...

Страница 12: ...d and the previous screen will be displayed To jump from the level Info directly to the level Setup press the rotary switch a bit longer and then release it while an Info screen is displayed Longer th...

Страница 13: ...ng the operation condition is displayed This screen is the home screen It shows the current temperature Temp and relative humidity RH This screen shows the current CO concentration detected by the CO...

Страница 14: ...e percent value represents the power transmitted to the fan The rpm value represents the fan s actual rpm The rpm value is not transmitted from all EC fans The rpm value can only be displayed if the c...

Страница 15: ...switch while this screen is displayed Climate In this section all setpoints desired values associated with temperature or humidity can be configured For each temperature or humidity setpoint a separa...

Страница 16: ...This will extract the humidity from the grow room given that the humidity of the fresh air is lower when inside the grow room This function is independent of whether a humidifier or dehumidifier is co...

Страница 17: ...eight width m m m m Enter the flow set on the CO armature or specified for your CO generator Unit l min litres minute The table below can be used as rough reference for the CO flow Room volume CO flow...

Страница 18: ...ve pressure can be set Separate values for day and night are available The factory settings are a good starting point for many setups Considerations for the optimum settings are Reasonable noise of th...

Страница 19: ...g is entered the message AC intake exhaust OFF is displayed In order to not turn off the corresponding fan the value for intake exhaust MIN MAX must be grater then the corresponding value AC turnoff I...

Страница 20: ...ue of 10 is set this means that the intake fan will always turn 10 less compared to the exhaust fan With a pressure sensor connected The setting limits the speed of the intake fan compared to the exha...

Страница 21: ...Event Timer times event start and event duration can be set e g event 1 start 14 30 hh mm event 1 duration 00 10 00 hh mm ss One or more events can be assigned to one power socket e g function out 1 e...

Страница 22: ...or 1 10V input For lights with a 0 10V input the brightness control as well as the turnoff is done with the 0 10V signal The mains supply of the lights doesn t have to be switched off in order to swi...

Страница 23: ...low the fan speed can be reduced is depending on the particular AC fan To avoid driving the AC fan to low a value for switch off is defined In order to not turn off the corresponding fan the value for...

Страница 24: ...average minimum maximum It defines which value is used for the corresponding function For these values settings are available RH Humidity captured by sensors RH T T Temperature captured by sensors RH...

Страница 25: ...fter a successful transfer of the filter value a message similar to the Apply calibration In order to restore all factory settings choose OK and confirm by pressing the rotary switch Please note that...

Страница 26: ...The sockets of GROWBASE are not optimized for switching LED luminaires or energy saving lamps To guarantee that the luminaires are completely switched off the 4th socket of the GROWBASE PRO controller...

Страница 27: ...rmat The firmware file has to be on the top level of the folder structure It may not be saved inside a folder The number of firmware files saved on one USB drive is limited to 20 files The name of a f...

Страница 28: ...ive pressure value If the value is too high the speed of the supply air fan will oscillate With a small value the negative pressure control reacts less responsive to changes in the currently measured...

Страница 29: ...er is following a PD or a P algorithm Hysteresis humidifier Set the hysteresis for the control of a humidifier here The hysteresis determines how often the humidifier is switched on and off and how ex...

Страница 30: ...connect lights with an 0 10 1 10V input or DC relays contactors use a suitable cable available as an accessory The assignment of the RJ45 jack labelled Lights 0 10V is shown in the following figure l...

Страница 31: ...mation only and has no influence on the control or function Function colour EC standard Pin RJ45 10V red 3 0 10V yellow 4 GND 0V blue 5 Pulse rpm white 6 Table 1 What to do if there are problems Probl...

Страница 32: ...r exhaust air AC The socket Multifunctional Out 4 is not switched on The 2nd power cable for the 4th socket is not connected Connect both power cables to the controller Table 2 Technical data Dimensio...

Страница 33: ...ng this period is to repair or replace the defective part or product with a comparable part or product at GrowControl s sole discretion Except for such replacement the sale or other handling of this p...

Страница 34: ...ry Version 1 0 0 rev1 en created on 26 10 2021 English translation Version 1 0 0 created on 13 06 2020 First release German version Refers to firmware version 5045 0 00 04 and higher Version 1 0 0 rev...

Страница 35: ...Instruction manual 1 0 0 rev1 en GROWBASE 35 V1 0 0 rev1 en GrowControl Excepting errors and changes...

Отзывы: