Instruction manual 1.0.0 rev1 en
GROW
BASE
15
and how long it takes until the next
switching.
This display shows the current percentage
with which a light, that is controlled via the
0-10/1-10V interface, is lit. (dimming)
This display shows the system's current
time and whether it is "day" or "night". This
is determined by the times “Start of day”
and “End of day”.
If the CO
₂
control is active, "CO2" is
displayed here. The CO
₂
mode is only
active during the day.
This display shows the remaining time for
switching an output for which the function
“interval” is selected to switch-on or
switch-off.
This screen shows the current desired value
for the room temperature. When a change
between day/night/CO
₂
occurs, the
transition to the new temperature setpoint
is done slowly following a ramp.
Additional information can be found in the
appendix in chapter 9.
To enter menu level “setup”, press the
rotary switch while this screen is displayed
Climate
In this section all setpoints (desired values) associated with temperature or humidity can be
configured. For each temperature or humidity setpoint, a separate value for day and night is
available. The current clock time and the times for “start of day” and “end of day” in section
“timing setup” determine when the controller is working in day mode or in night mode.
RH
(Relative humidity): These settings define when a humidifier or dehumidifier is switched on
or off. Depending on the settings for the dehumidification mode, the exhaust airflow can be
increased and a heater can be switched on in order to decrease humidity.
Setpoint temperature:
These values set here define the desired temperature values for
controlling the air temperature by the exhaust (and intake) fans.
The sensor readings that are relevant for previously mentioned functions are captured by the
supplied sensor for relative humidity and temperature.