Instruction manual 1.0.0 rev1 en
GROW
BASE
12
Operation
The controller is operated via a menu, which is divided into two levels. It is controlled by turning
or pressing the rotary switch (2).
•
On level
“Info”
, different information is displayed.
•
On level
“Setup”
, all settings can be configured. This level is grouped in different
topics.
In the right area of the display, currently available menu options are displayed by these
symbols:
F
Enter (press)
BC
Go to next menu page (rotate)
k
Change value (rotate)
i
Info screen
Press the rotary switch a bit longer* and then release it in order to jump from any “setup
screen” to the screen
„Save&Apply”
.
If the rotary switch is pressed again, the changed settings will be saved and applied and the
previous screen will be displayed.
To jump from the level
“Info”
directly to the level
“Setup”
press the rotary switch a bit
longer* and then release it while an
“Info”
screen is displayed.
*Longer than half a second but shorter than 4 seconds.
The changing of a certain setting is explained below with the desired humidity value during
daytime as an example:
1.
In the menu in section “climate setup”,
choose the screen
“Set desired RH
day”
.
In order to get to this screen
starting at the home screen, follow
these steps:
a.
Rotate the rotary switch one step
CCW (counter clock wise). “Press to
enter setup” is displayed.
b.
Press the rotary switch. „Climate
setup” is displayed.
c.
Press the rotary switch. The following
screen is displayed:
2.
Press the rotary switch. Now the
symbol
k
appears and the value to be
set blinks.
3.
Choose the desired value by turning
the rotary switch.
Set desired RH
F
dayC 65A
BC
Desired
DF
RH
C
65
A
E