![Groeneveld EG1703P03 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/groeneveld/eg1703p03/eg1703p03_general-manual_2268476019.webp)
Automatic Greasing System
Twin-3
Principle of operation
19
Da
te
of
is
sue
:
Ja
nu
ar
y 2
0
1
1
EG1703P03
2.5
Pressure switch
The pressure switch notifies the control unit that sufficient pressure has been built up during the
pumping phase and stops the pump. When the required pressure is not reached, the pumping
phase is only ended after reaching the set maximum pumping time. An alarm will follow (signal
lamp).
Preferably the pressure switch is mounted on the distribution block, located the farthest from the
pump. This is done to be sure that the required grease pressure of 100 bar also reaches the last dis-
tribution block. When for practical considerations the switch is placed somewhere in the middle or
at the beginning of the greasing system, a switch with a higher switch-pressure is applied. Pressure
switches are delivered with switch-pressures of 100, 125, 150 or 175 bar.
2.5.1
Principle of operation
The principle of operation of the pressure switch is explained in three phases.
Phase 1
During this phase no pressure is on channel A and B. There is also no pressure in chamber (1). Spring
(10) pushes switch piston (2) to the left. The electrical contact (3 and 4) is open.
Figure 2.12
First phase
Phase 2
During pumping phase A grease is pressed into channel A. While the grease pressure is built up,
piston (6) is pushed to the right. Chamber (1) is connected to channel A (through the channels 7, 8
and 9).
As soon as the pressure in chamber (1) is more than the pressure force of the spring (10), piston (2)
goes to the right. The electrical contact (3 and 4) is closed by the contact plate (5).
B
A
1
2
1
0
3
4