Power Input 

 

 

The 

GRN 

Batten 3-54 uses a Neutrik PowerCon inlet rated at 20A, 250V as standard. The Fixture will 

 

operate at 

120VAC or 220VAC See below for voltage adjustment instructions

.  

 
 

NOTE: 

 

Disconnect power before adjusting the input voltage

 

 
 

Fuse – 4A, 250V    Fuse must be replaced with the proper type and rating

 

Page 3 

 - 

Open the bottom of the fixture to expose the Power supply 

 

-Remove Yoke 

 

-Remove 4 screws on plastic end caps 

 

-Remove 6 screws on bottom cover plate

 

To Adjust your input voltage 

 

-  

Insert a small screwdriver or similar tool through the PCU grate and toggle the switch making note of 

 

the position in relation to the yellow voltage sticker.  If the sticker is missing toggle switch to the left 

 

position for 110v and to the right position for 220V

 

Содержание Batten 3-54

Страница 1: ...GRN Batten 3 54 v5 4 GRNlite com GRN Batten 3 54 User Manual v5 4...

Страница 2: ...1 About the GRN Batten 3 54 2 Power input and Voltage adjustment 3 Data input 4 Fixture Placement Hanging Maintenance 5 Fixture Menu Options 6 Cell Configuration for DMX Channel Modes 7 DMX Channel Mo...

Страница 3: ...ation which can damage the retina permanently Use extreme caution when servicing the fixture or when in close proximity to the powered fixture Never look directly into the front of the fixture when it...

Страница 4: ...gives a multitude of advantages unique to LED technology The RGBAW LEDs give a much wider color gamut than the usual RGB systems and with dramatically increased power efficiency over older technologie...

Страница 5: ...must be replaced with the proper type and rating Page 3 Open the bottom of the fixture to expose the Power supply Remove Yoke Remove 4 screws on plastic end caps Remove 6 screws on bottom cover plate...

Страница 6: ...d has a 3 pin XLR for DMX data input and thru The Data connections for 3 pin XLR are as follows Pin 1 GND Shield Pin 2 Data Pin 3 Data Adapting a 5 pin XLR data feed to 3 pin XLR is as follows 5 pin X...

Страница 7: ...the clutch handle clockwise to retighten A safety cable should be used for every fixture other than those that use ground support NOTE The GRN Batten fixtures may be mounted in any orientation as lon...

Страница 8: ...ot active in any other mode of operation Page 6 Mode Function Run Mode DMX on off Slav ON Off FADE Mode Preprogrammed single fade chase Speed adjustable only FLOW Mode Preprogrammed flow chases 0 9 ad...

Страница 9: ...N Batten 3 54 v5 4 GRNlite com Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 The GRN Batten 3 54 has 6 cells that can be addressed individually or in various groups GRN Batten 3 54 cell configuration Page...

Страница 10: ...Description 1 Red 0 255 Proportional All Cells 2 Green 0 255 Proportional All Cells 3 Blue 0 255 Proportional All Cells 4 Amber 0 255 Proportional All Cells 5 All Cells White 0 255 Proportional 6 All...

Страница 11: ...Cells 4 5 6 Green 0 255 Proportional 8 Cells 4 5 6 Blue 0 255 Proportional 9 Amber 0 255 Proportional Cells 4 5 6 10 Cells 4 5 6 White 0 255 Proportional 11 All Cells Macro Sets a default look 12 All...

Страница 12: ...Cells 1 2 White 0 255 Proportional 6 Cells 3 4 Red 0 255 Proportional 7 Cells 3 4 Green 0 255 Proportional 8 Cells 3 4 Blue 0 255 Proportional 9 Amber 0 255 Proportional Cells 3 4 10 Cells 3 4 White...

Страница 13: ...n 0 255 Proportional 13 Cell 3 Blue 0 255 Proportional 14 Cell 3 Amber 0 255 Proportional 15 Cell 3 White 0 255 Proportional 16 Cell 4 Red 0 255 Proportional 17 Cell 4 Green 0 255 Proportional 18 Cell...

Страница 14: ...r Neutrik Powercon 20A in and through Operating Current 1 8A 208V 60Hz 2 3A 110V 60Hz Mains Fuse 4A 250V Weight 16 5 lbs 7 5 kgs Dimensions 24 L x 8 25 W x 4 H 609 mm x 210mm x 104mm Output 5750 Lux 1...