![GRNLITE Batten 3-54 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/grnlite/batten-3-54/batten-3-54_user-manual_2268221005.webp)
GRN Batten 3-54 v5.4
Power Input
The
GRN
Batten 3-54 uses a Neutrik PowerCon inlet rated at 20A, 250V as standard. The Fixture will
operate at
120VAC or 220VAC See below for voltage adjustment instructions
.
NOTE:
Disconnect power before adjusting the input voltage
Fuse – 4A, 250V Fuse must be replaced with the proper type and rating
Page 3
-
Open the bottom of the fixture to expose the Power supply
-Remove Yoke
-Remove 4 screws on plastic end caps
-Remove 6 screws on bottom cover plate
To Adjust your input voltage
-
Insert a small screwdriver or similar tool through the PCU grate and toggle the switch making note of
the position in relation to the yellow voltage sticker. If the sticker is missing toggle switch to the left
position for 110v and to the right position for 220V