Introduction

These  noise  reduction  kits  significantly  reduce 
the noise level of cyclone dust collectors without 
causing efficiency loss.

Installation Instructions

The mufflers are best installed in the outlet hose, 
as close to the filter as possible. The installation 
consists of removing a section of the outlet hose  
and  installing  the  muffler  in  its  place.  Wire  hose 
clamps are provided to secure the muffler to the 
outlet hose (see 

Figure 1

).

To install the muffler:

1. 

Measure  the  size  of  the  muffler  body  (see 

Figure 2

).

2.

  Using  a  felt-tip  marker,  mark  a  section  of 

the outlet hose equal in length to the muffler 
body. IMPORTANT: Leave at least 4" of out-
let hose between the filter and the muffler.

3.

  Remove the portion of the outlet hose marked 

in 

Step 2

.

4.

  Fit the wire hose clamps over the ends of the 

outlet  hose  and  slide  them  back  at  least  2" 
from the opening.

5.

  Fit  the  ends  of  the  outlet  hose  completely 

over the ends of the muffler.

6.

  Slide the wire hose clamps down to the end 

of the hose near the body, then tighten them 
to secure the muffler in place.

MODEL H8165/66/67/68

NOISE REDUCTION KIT 

FOR CYCLONE DUST 

COLLECTORS

�������

����

Figure 2. 

Size of muffler body.

If you need help installing the noise reducing kit, 
call our Tech Support at: (570) 546-9663.

COPYRIGHT © NOVEMBER, 2006 BY GRIZZLY INDUSTRIAL, INC.

WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE

 OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.

 #TR8803  PRINTED IN TAIWAN

Figure 1. 

Noise reducing kit installed.

Wire Hose 

Clamp

Muffler

Wire Hose 

Clamp