Model G0936 (Mfd. Since 06/21)
-33-
6. Loosen (2) set screws on 45° stop nut shown
in
Figure 42.
7. Adjust 45° stop nut shown in Figure 42 until
platen is 45° to table, then tighten set screw
from
Step 6 to secure.
— If platen is 45° to table, but angle scale
does not display 45°, angle scale needs to
be calibrated (perform
Step 7 then refer to
Calibrating Platen Angle Scale).
8. Install pulley cover.
Figure 42. Location of 45° stop nut.
45° Stop Nut
x 2
Figure 41. Location of pulley cover and
fasteners.
x 4
Pulley
Cover
5. Remove (4) Phillips head screws and flat
washers shown in
Figure 41 to remove pul-
ley cover.
Calibrating Platen
Angle Scale
The platen angle scale was calibrated at the fac-
tory, but if it the actual platen angle in relation to
the table is different than the angle displayed on
the scale, the scale will need to be calibrated.
Tools Needed
Qty
90° Square ........................................................ 1
Phillips Head Screwdriver #2 ............................ 1
Open-End Wrench 12mm .................................. 1
To calibrate platen angle scale:
1. DISCONNECT MACHINE FROM POWER!
2. Refer to Steps 1
—
6 of Squaring Platen to
Table on Page 31.
3. Loosen jam nut shown in Figure 43.
4. Adjust adjustment nut shown in Figure 43
until scale displays 0°, then tighten jam nut
from
Step 3 to secure.
5. Install back cover and left side cover.
Figure 43. Scale adjustment components.
Jam Nut
Adjustment
Nut