Model G0726 (Mfg. Since 7/11)
-31-
Tools Needed
Qty
Hex Wrench 8mm .............................................. 1
Wrench or Socket 12mm ................................... 1
To operate the X- or Y-axis power feed:
1. Loosen appropriate table locks for the desired
path of travel.
2. Loosen limit stop hex bolt or cap screw, posi-
tion limit stop along slot to limit travel, then
re-tighten fastener to secure it in place.
3. Rotate speed dial to slowest speed and set
direction lever for desired direction of travel.
4. Use power switch to turn power feed ON, and
adjust speed dial for desired feed rate.
5. When you are finished using power feed,
position the direction lever to the center OFF
position, then use power switch to turn unit
OFF.
Stay clear of the spinning ball handles when
using the power feeds to prevent entangle-
ment injuries.
Z-Axis Crank & Power Feed
Graduated Dial Increments
Resolution
Each Mark ................................................. 0.001"
One Revolution .......................................... 0.100"
When the vertical crank handle is engaged
for manual operation, the safety switch below
the crank disables the vertical power feed (see
Figure 30).
Push the handle into the leadscrew to engage
it for manual operation. Pull it out to dis-engage
it from the safety switch, which enables the use
of the vertical power feed buttons on the control
panel.
Figure 30. Z-axis crank and safety switch.
Z-Axis Safety
Switch
Crank