-70-
G0677 24" Planer/Sander
READ ELECTRICAL SAFETY
ON PAGE 61!
Electrical Components D
Figure 96. Lower table limit switch.
1NC
2NC
3NO
4NO
18
Table Limit
Switches
Ground
U2
V2
W2
W1
W5
U1
U5
V1
V5
W1
U1
V1
Feed Motor 220V
16
Feed Motor 440V
16
18
Ground
Ground
U2
V2
W2
V1
V5
W1
W5
U1
U5
V2
W2
U2
18
Elevation Motor 220V
17
Ground
U1
V1
W1
V2
V5
W2
W5
U2
U5
Elevation Motor 440V
17
W2
V2
U2
1NC
2NC
3NO
4NO
18
V2
U1
W2
U2
V1
W1
W5
U5
V5
U1
W1
V1
18
18
13
(Upper)
15
(Lower)
Figure 97. Feed motor 220V wiring.
13, 15, 16, 17
Jumper
Figure 98. Elevation motor wiring.
Note: Be sure to remove the jumpers
(see
Figures 97 & 98) from the feed
and elevation motor junction boxes
when rewiring the motors to 440V.
Jumper