G0677 24" Planer/Sander
-23-
Recommended
Adjustments
For your convenience, the adjustments listed
below have been performed at the factory and
require no further adjustment. However, we rec-
ommend that you verify that the adjustments are
correct and to your satisfaction.
Recommended adjustment checklist:
1.
Pressure Rollers
(
Page 20
).
2.
Oscillation Speed
(
Page 27
)
.
3.
Air System (
Air Regulator to 75 PSI;
Page
38
)
.
4.
Table Calibration
(
Page 42
)
.
5.
Belt Tracking
(
Page
44
)
.
6.
Table Parallelism
(
Page 46
)
.
7.
V-Belt Tension
(
Page 50
)
.
8.
Feed Belt Tension
(
Page 57
)
.
9.
Feed Belt Tracking
(
Page 57
)
.
9. Press the FEED BELT START then the
FEED BELT STOP buttons (see
Figure 25,
Page 24). The feed belt should start, run in
the correct direction and stop smoothly.
10. Press the SANDING BELT START then the
SANDING BELT STOP buttons. The sanding
belt should start, run in the correct direction,
and stop smoothly.
— When operating correctly, the machine
runs smoothly with little or no vibration or
rubbing noises.
However, you will hear an air leaking sound
from the oscillation controller fork jet (
Figure
19).
— Investigate and correct strange or unusual
noises or vibrations before operating the
machine further. Always stop the machine
and disconnect it from power before inves-
tigating or correcting potential problems.
11. Press the front STOP button to stop the
machine.
12. WITHOUT resetting the switch, press the
FEED BELT START button. The machine
should not start.
— If the machine does not start, the STOP
button safety feature is working correctly.
— If the machine does start (with the STOP
button pushed in), immediately disconnect
power to the machine. The STOP button
safety feature is not working correctly. This
safety feature must work properly before
proceeding with regular operations. Call
Tech Support for help.
13. Reset the STOP button.
14. Press the rear STOP button and repeat
Steps 12–13.
15. Press the FEED BELT START button, then
press the emergency stop plate. The sander
will come to a complete stop.
— If the feed belt does not come to a com-
plete stop, the emergency stop plate is not
working correctly. Call Tech Support for
help.
16. Unlock and slightly open the right and left
access doors until you hear a "click," indicat-
ing that the door limit switches have been
triggred.
— If the machine does not start, the door limit
safety switches are working correctly.
— If the machine does start, immediately dis-
connect power to the machine. The door
limit switches are NOT working correctly.
This safety feature must work properly
before proceeding with regular operations.
Call Tech Support for help.