![Grizzl-E GR1-14-18 Series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/grizzl-e/gr1-14-18-series/gr1-14-18-series_user-manual-and-installation-manual_2265884023.webp)
23
7.2 LED Fault Indicator
In the instance of a fault, it is recommended that you perform a reset:
1. Count the number of flashes as described above and record the error type.
2. Unplug the charging Connector from your EV
3. Turn off the power to the Charging Station by switching the upstream circuit breaker to
the “OFF” position
4. With the circuit breaker in the “OFF” position, wait 1-2 minutes and then switch the
upstream circuit breaker back to the “ON” position
5. Confirm the Fault light is no longer present.
6. If the Fault light remains, please contact United Chargers. Download the
and send an email to [email protected]. Indicate the number of red
flashes.
LED Indicator
# of Flashes
Error Description
Red Flashing
1
Lost ground - AC Line1
Red Flashing
2
GFCI High Leakage
Red Flashing
3
Relay is stuck
Red Flashing
4
GFCI Low Leakage
Red Flashing
5
High temperature of the
module
Red Flashing
6
High temperature of the
relay-
Red Flashing
7
Pilot state is Status E
Red Flashing
8
Pilot state is Status F
Red Flashing
9
Diode error
Red Flashing
10
Over Current
Red Flashing
12
Application Error
7.3 Reset Charger
The number of red flashes shows the type of fault: