7.1 Setting operating mode
By the dip-switch panel it is possible to select one of the following operating modes:
• With DMX512 controller
Each fixture is controlled from DMX512 signal control.
• MASTER-SLAVE or AUTOMATIC mode
The fixture will operate independentely with no need for controllers
(see chapter 8.0 Master-Slave and Automatic mode).
7.2 Setting DMX address
The number of DMX channels used by the unit to operate will depend from value of dip-switches n°10.
The following table reads the functions corresponding to the dip-switches values.
In case of more units operating with synchronized output, the first unit will be set with address 001, the second unit
with address 005, the third unit with address 009, etc.
In case of more units operating with indipendent output, the first unit will be set with address 001, the second unit
with address 017, the third unit with address 033, etc.
7.2 DMX functions
7.2.1 DMX functions with 4 synchronized output
7.0 Use of the unit
Dip 10
Funzione
Canali DMX
OFF
4 indipendent output
16 DMX channels
ON
4 synchronized output
4 DMX channels
Example
Unit with address 001
(dip-switch n°1 = ON)
and 4 synchronized output (4 DMX channels)
Example
Unit with address 017
(dip-switch n°1 and 5 = ON)
and 4 indipendent output (16 DMX channels)
Channel Function
Value
Description
1
Red
0-255
Proportional control 0-100% of the Red color
2
Green
0-255
Proportional control 0-100% of the Green color
3
Blue
0-255
Proportional control 0-100% of the Blue color
4
Dimmer
Strobe
0-15
Luminous output intensity 100%
16-150
Proportional control of the luminous output intensity 100-0%
151-160
Luminous output intensity 0%
161-255
Proportional control of the strobe effect 0-100%
English