6.4 Projectors connection
The Transformer Box has been designed to run a maximum number of 4 units of the Waterled MK2.
The DMX signal is to be connected by using a shielded cable designed for devices RS-485.
The unit is fitted with internal pins for the connection of the projectors, as shown in the following pictures.
1.
Untighten the 4 screws
“A”
and open the units.
2.
Let the projectos cables pass through the cable glands
“N
” lo-
cated onto the unit body and connect to the pin
“P”
.
The connection of the cable to the unit must be performed re-
specting the label next to the terminal box, .
3.
Close the unit again by tighten the screw
“A”
previously removed.
6.5 Powering up the unit
After performing all the actions described in the previous paragraphs, it is possible to proceed and power up the
unit.
In case of DMX signal connected, the LED will be steady on, while in the absence of DMX signal the LED will off.
A
N
ø9 MIN
ø14 MAX
Projectors cable size
DATA-
DATA+
VDC+
VDC-
GND (HOSE)
P
22
English