Grindmaster American Metal Ware TEA-300 Скачать руководство пользователя страница 1

1103 Form # AM-325-04

Part # A090-103

American Metal Ware

®

Tea Brewers

Operation and Instruction Manual

for

TEA-300

Tea Brewer Series

Grindmaster Corporation, 1999
PRINTED IN THE USA

TABLE OF CONTENTS

Prior authorization must be obtained
from Grindmaster Corporation for all
warranty claims.

Warning Labels  . . . . . . . . . . . . . . . . . . . . . . . .2

Set Up/Position  . . . . . . . . . . . . . . . . . . . . . . . .3

Water Hook-Up . . . . . . . . . . . . . . . . . . . . . . . . .3

Electrical Requirements  . . . . . . . . . . . . . . . .3-4

Initial Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . .4

Use Control Functions  . . . . . . . . . . . . . . . . . . .4

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Adjustments  . . . . . . . . . . . . . . . . . . . . . . . . .5-6

Cleaning Procedures  . . . . . . . . . . . . . . . . . .6-7

Service  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8

Troubleshooting Guide  . . . . . . . . . . . . . . . .9-10

Exploded View . . . . . . . . . . . . . . . . . . . . . .11-12

Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . .13

Grindmaster Corporation

4003 Collins Lane
Louisville, Kentucky 40245 USA
(502) 425-4776  800-695-4500
(800) 568-5715 

(technical service only)

FAX (502) 425-4664
www.grindmaster.com

TEA-300

Содержание American Metal Ware TEA-300

Страница 1: ...ion for all warranty claims Warning Labels 2 Set Up Position 3 Water Hook Up 3 Electrical Requirements 3 4 Initial Start Up 4 Use Control Functions 4 Operation 5 Adjustments 5 6 Cleaning Procedures 6 7 Service 7 8 Troubleshooting Guide 9 10 Exploded View 11 12 Wiring Diagrams 13 Grindmaster Corporation 4003 Collins Lane Louisville Kentucky 40245 USA 502 425 4776 800 695 4500 800 568 5715 technical...

Страница 2: ......

Страница 3: ...RESULT IN SEVERE BURNS WARNING BURN HAZARD HOT LIQUIDS AND SURFACES ARE PRESENT IN THIS EQUIPMENT TO AVOID BURNS USE CAUTION WHEN CLEANING RINSE HOT PARTS WITH COLD WATER BEFORE CLEANING USE GLOVES OR HEAVY CLOTH WHEN REMOVING HOT PARTS FROM BREWER WARNING ELECTRIC SHOCK HAZARD NEVER USE THE GROUND CONDUCTOR AS A NEUTRAL THIS COULD CAUSE ELECTROCUTION CAUTION HOT LIQUID HAZARD TEA BASKET CONTAINS ...

Страница 4: ...ACKFLOW PROTECTION TO COMPLY WITH APPLICABLE FEDERAL STATE AND LOCAL CODES 5 Installing a filtering system can improve the taste of brewed tea and extend the life of the brewer The use of a filter is especially important if your water has a high calcium lime chlorine or iron content Contact our Technical Service department to select the filter for your water conditions Electrical Requirements IMPO...

Страница 5: ...his occurs press the Stop switch At this point the water tank is primed 7 Turn off the power switch to energize the heating element 8 When the water temperature has reached the preset temperature the Water Hot lamp will illuminate This may take between 15 and 35 minutes 9 Check the brewer water temperature at the sprayhead If the temperature needs to be adjusted refer to Adjustments section of thi...

Страница 6: ...e hot tea is mixed with cold water in the dispenser Add sweetener if desired and serve over ice 8 After brewing place the cover over the tea dispenser to keep fresh 9 Dump the used tea and filter from the basket and rinse for the next brew Adjustments All adjustable components are located under the top cover or behind the lower front cover Timer Adjustment Change timer setting if the total volume ...

Страница 7: ...ards 3 Locate thermostat mounted on tank 4 Turn the shaft clockwise to increase the water temperature counter clockwise to decrease water temperature Refer to Figure B 5 Re install top cover with screw then plug unit in and return to use Bypass Adjustment Change bypass adjustment if desired volume of brewed liquid requires adjustment 1 Shut off power and unplug the brewer 2 Remove the lower front ...

Страница 8: ...nd can be used to help determine the cause of problems with the equipment An illustrated parts breakdown follows and will aid in correctly identifying replacement parts For factory assistance call 1 800 695 4500 between 8 00 a m and 5 00 p m Eastern time Finally wiring diagrams are provided for the various models covered by this manual To Drain Water Tank 1 Turn off the power to the brewer and all...

Страница 9: ...tank Lift the tank cover with the heating element attached 5 Remove the thermostat bulb bracket retaining the thermostat bulb to the heating element 6 Remove the heating element from the tank cover 7 Replace the heating element with the sealing washers in the same configuration hold the element so that it does not twist when tightening the element nuts 8 Reinstall the tank cover in reverse order b...

Страница 10: ...during brewing Add screen kit to brew basket Unpleasant taste Tea dispenser or brew basket needs cleaning Water tank has lime build up Taste is coming from water supply Clean and sanitize De lime water tank Install a water filtration system Brew volume too large or too small Timer setting set too long or too short Water service not supplying adequate water pressure or flow rate Adjust timer to des...

Страница 11: ...te thermostat If no remedy or thermostat does not cycle replace thermostat Check each electrical connection of heating circuit Recovery time is very long Bad electrical connection of heating circuit Bad high limit switch Faulty heating element Check each electrical connection of heating circuit Check resistance across high limit switch should be no resistance If resistance present then replace Che...

Страница 12: ...American Metal Ware Tea Brewers Page 11 Tea 300 Isometric ...

Страница 13: ...American Metal Ware Tea Brewers Page 12 Tea 300 3 Gallon Dispenser Isometric ...

Страница 14: ...American Metal Ware Tea Brewers Page 13 Tea 300 Wiring Schematic ...

Страница 15: ......

Страница 16: ......

Отзывы: