![Grindex 8120.280 Sandy Inox Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/grindex/8120-280-sandy-inox/8120-280-sandy-inox_installation-operation-and-maintenance-manual_2265326027.webp)
CAUTION: Crush Hazard
The starting jerk can be powerful. Make sure nobody is close to the unit when it
is started.
NOTICE:
Make sure that the rotation of the impeller is correct. For more information, see
Check the impeller rotation.
1. Inspect the pump. Check that there is no physical damage to the pump or
cables.
2. Check the oil level in the oil housing.
3. Remove the fuses or open the circuit breaker, and check that the impeller can
rotate freely.
WARNING: Crush Hazard
Never put your hand into the pump housing.
4. Check that the monitoring equipment (if any) works.
5. Check that the impeller rotation is correct.
6. Start the pump.
5.3 Clean the pump
The pump must be cleaned if it has been running in very dirty water. If clay,
cement or other similar dirt is left in the pump it may clog the impeller and seal,
preventing the pump from working.
Let the pump run for a while in clean water, or flush it through the discharge
connection.
5 Operation
8120.280 Sandy Inox Installation, Operation, and Maintenance Manual
25