For more permanent installations with a heavily contaminated pumped liquid, a
settling pump-sump is recommended.
WS001380B
Figure 1: Settling pump-sump
Discharge line requirements
The discharge line can be run vertically or horizontally, but must be without
sharp bends.
Proper horizontal and vertical installation
Improper installation
with a sharp bend
WS001379A
WS001346A
Fasteners
• Only use fasteners of the correct size and material.
• Replace all corroded or damaged fasteners.
• Make sure that all the fasteners are correctly tightened and that there are no
missing fasteners.
4.3 Install
The pump is transportable and intended to operate either completely or partially
submerged in the pumped liquid. The pump is equipped with a connection for
hose or pipe.
These requirements and instructions only apply when the installation is made
according to the dimensional drawing.
1. Run the cable so that it has no sharp bends, is not pinched, and cannot be
sucked into the pump inlet.
2. Connect the discharge line.
The discharge line can be run vertically or horizontally, but must be without
sharp bends.
3. Lower the pump into the sump.
The cable must not be used for this purpose. You should attach a rope or
similar to the handle or the eye bolts for lowering and lifting the pump.
Heavier pumps must be lifted and lowered down by crane. Suspend the pump
by the lifting handle or the eye bolts with chains or wires.
4. Place the pump on the base and make sure it cannot fall over or sink.
4 Installation
8120.280 Sandy Inox Installation, Operation, and Maintenance Manual