background image

6

INTRODUCTION

OVERVIEW OF THE GATE OPENER 

4

Gate 
Opener

Limit Switch 
Brackets

Limit Switch 
Brackets

Gate

Remote 
Control

Transformer Box
mounted near 
240V power supply 
(MGTR3-120VA)

NOTE: Only required 
for GLD-GO-LV 
low voltage 24V 
sales kit

GLD-GO – MAINS VOLTAGE 240V SLIDE GATE OPENER INSTALL OR                   

GLD-GO-LV – LOW VOLTAGE 24V SLIDE GATE OPENER INSTALL 

Gate 
Opener

Limit Switch 
Brackets

Limit Switch 
Brackets

Gate

Remote 
Control

Persons are to keep clear! The gate is able to 

be moved without prior warning. 
Do not let children operate the gate or play in 

the gate area.

Moving Gate Can Cause

Serious Injury Or Death

132A3224-01

WARNING

Warning Label 
placed within 
the inside of 
the post

Transformer Box
mounted near 
240V power supply 
(MGTR3-120VA)

NOTE: Only required 
for GLD-GO-LV 
low voltage 24V 
sales kit

GLD-GO – MAINS VOLTAGE 240V SLIDE GATE OPENER INSTALL OR            

GLD-GO-LV – LOW VOLTAGE 24V SLIDE GATE OPENER INSTALL

Warning Label is provided with each sales kit (GLD-GO & GLD-GO-LV). The warning label must 
be placed on the inside of the post.

INSTALLING THE WARNING LABELS 

5

Persons are to keep clear! The gate is able to 

be moved without prior warning. 
Do not let children operate the gate or play in 

the gate area.

Moving Gate Can Cause

Serious Injury Or Death

WARNING

132A3224-01

TOOLS NEEDED

3

Содержание LG Drive GGS1000

Страница 1: ...patible with Security 2 0 accessories Compatible with Grifco Battery Backup and myQ Internet Gateway Slide Gate Opener GLD GO GLD GO LV Installation and Operating Instructions INSTRUCTION MANUAL Compa...

Страница 2: ...ates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in minor or moderate i...

Страница 3: ...y respecting the given safety distances in accordance with the AS NZS 60335 1 in conjunction with AS NZS 60335 2 103 and or with safety devices e g safe edge Testing of the safety function of the driv...

Страница 4: ...Initial Setup 20 BASIC SETTINGS 21 26 Limit and Force Learning 21 Remote Control Behaviour 21 IR Behaviour 21 Input Command 22 Pedestrian Command 22 Delay Motor 2 in Open and Close Direction 22 23 Tim...

Страница 5: ...tains the opener its hardware accessories four metres of rack and a transformer MGTR3 120VA only for the GLD GO LV sales kit Main AC Supply 220 240Vac 50 60Hz Motor Voltage 24 Vdc Input Power 150 W Am...

Страница 6: ...play in the gate area Moving Gate Can Cause Serious Injury Or Death 132A3224 01 WARNING Warning Label placed within the inside of the post Transformer Box mounted near 240V power supply MGTR3 120VA N...

Страница 7: ...that the Low Voltage LV power cable is run inside conduit to the opener as per local installation requirements Suitable cable glands must be used that provide sufficient cable restraint against a mini...

Страница 8: ...ight 1000kg Maximum Gate Width 12m Conduit and Concrete Pad Trench and install conduit Before trenching contact underground utility authorities Conduit must be approved for low and mains voltage Consi...

Страница 9: ...ith a minimal distance of approximately 1 2cm between the rollers and gate Safety Safety entrapment protection devices are recommended to protect against any entrapment or safety conditions encountere...

Страница 10: ...plate Rack 270 mm 170 mm 60 mm Underneath the mounting plate is the concrete slab one of the two limit switch brackets Mounting plate Rack Rack 90 100mm Rack Rack Gate Rack 2 3mm PLANNING CONTINUED 6...

Страница 11: ...ounting plate 90 100mm Rack 1 Position the base mounting plate as required referring to the planning section figure 1 2 Mark and drill the four masonry anchor holes figure 2 NOTE Position the power co...

Страница 12: ...t of the drive gear with the gate rack figure 1 figure 2 1 Manually move the gate into OPEN position 2 The nylon rack can be attached with screws Put the first rack segment at the end of the gate so t...

Страница 13: ...g cover over the opener and move the gate manually to the open and close positions to ensure that the limit switch brackets do not come into contact with the gate structures or the gate opener Positio...

Страница 14: ...ns be sure to follow all specifications and warnings Failure to do so may result in SEVERE INJURY to persons and or damage to the opener ALL electrical connections MUST be made by a licensed electrici...

Страница 15: ...ain access to the control board remove the opener cover The terminals for wiring accessories are directly accessible To get access to the programming buttons remove the transparent plastic cover and p...

Страница 16: ...0 0 0 4 3 2 1 1 2 3 3 1 2 1 2 12 13 14 4 11 10 9 8 7 6 5 1 3 2 3 4 2 1 3 2 1 2 1 3 2 1 3 2 1 2 1 1 2 1 2 2 1 2 1 1 2 1 2 5 4 3 2 1 6 7 8 9 10 2 1 1 1 1 2 1 1 1 1 Dual driver primary secondary SYNC Du...

Страница 17: ...r can only be connected to the Edge inputs 1 Remove the 8 2k resistor from the Edge inputs 2 Connect the 8 2k compatible edge sensor to the Edge inputs EDGE SE SE IR SENSOR GND IR3 IR2 IR1 COMMAND GND...

Страница 18: ...change the value on display The programming of the boards is divided in two steps 1 Basic including Initial Setup 2 Advanced Password Protected Settings Initial Set up includes Selection of motor typ...

Страница 19: ...E Lock E Lock 30 Ram Blow Setup additional electronic lock E Lock or Mag Lock options 31 Flashing Light Setup flashing light accessory 32 Pre Flashing Adjust pre flashing of flashing light accessory 3...

Страница 20: ...tion has been confirmed the screen will change to MAIN MENU DIRECTION MOTOR If there is a second slide gate opener to be setup press the button to scroll to the next menu option MAIN MENU DIRECTION MO...

Страница 21: ...tons to navigate through the options 3 You can select the following options OPEN CLOSE OPEN OPEN STOP CLOSE STOP OPEN STOP CLOSE OPEN OPEN ONLY 4 To confirm the setting press the P button to save and...

Страница 22: ...e following options No Second Delay Second Delay 3 Second Delay 4 Second Delay 4 To confirm the setting press the P button to save and return to the main menu screen S P MAIN MENU DELAY MOTOR 2 OPEN f...

Страница 23: ...ELAY MOTOR 1 CLOSE figure 1 TIMER TO CLOSE TTC 28 Within the Basic Setting navigate through the menu screen until you find MAIN MENU TIMER TO CLOSE 1 Press the P button to enter this setting figure 1...

Страница 24: ...COND REVERSAL S P REVERSE TO LIMIT S P CLOSE REV TO OPEN LIMIT OPEN REV 2 SECONDS figure 1 figure 2 figure 3 figure 4 BASIC SETTINGS E LOCK 30 Within the Basic Setting navigate through the menu screen...

Страница 25: ...U FLASHING LIGHT 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Disabled Continuous Flashing 4 To con...

Страница 26: ...ind MAIN MENU SOFT HARD START SETTING 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Soft Hard Start...

Страница 27: ...WORD CHANGE PASSWORD S P ENTER OLD PW 0000 S P ENTER NEW PW 0000 figure 1 figure 2 figure 3 CHANGE PASSWORD 1 Navigate the Menu screen till you get to MAIN MENU PASSWORD by pressing the and or buttons...

Страница 28: ...e force by 15 30 or 50 4 To confirm the setting press the P button to save and return to the main menu screen PASSWORD 37 ENTER PASSWORD 1 Navigate the Menu screen till you get to MAIN MENU PASSWORD b...

Страница 29: ...you find MAIN MENU SPEED MOTOR 1 2 CLOSE PW 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can increase the speed by 25 50 75 or 100 I...

Страница 30: ...this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Execute Factory Reset Exit 4 To confirm the setting press the P button to save and...

Страница 31: ...NDBY screen NOTE The transmitter s supplied with your opener are preprogrammed by the factory If you purchase additional transmitters the gate opener must be programmed to accept the new transmitter c...

Страница 32: ...compatible Ensure the Grifco gate opener is installed Purchase the gate myQ Connectivity Kit that includes 1 x myQ Gateway and 1 x 772ANZ Protector System Safety IR Beams Ensure the 772ANZ Protector...

Страница 33: ...th the gate myQ Connectivity Kit or as an individual accessory NOTE The Protector System Safety IR Beams 772ANZ must be installed and operational for myQ to operate myQ Gateway Connect the myQ Gateway...

Страница 34: ...BER from the bottom label of the myQ Gateway The serial number is a series of ten characters 0 9 or a f Be sure to use the correct characters e g a zero 0 instead of an O and keep the character spacin...

Страница 35: ...m Check for incorrect accessories wired into the IR terminals Check the Protector System for alignment or an obstruction Auto reset once obstruction is clear or Protector System is realigned may take...

Страница 36: ...te Auto reset once the issue has been resolved may take up to 16 seconds ERR MOTOR1 RPM ERR MOTOR2 RPM Motor is stalled or RPM is damaged Check if the motor is stalled or RPM is damaged Auto reset onc...

Страница 37: ...t shown 18 002A2331 6 Pin Wire Harness not shown 19 Model Vary Flashing Lamps not shown 20 Model Vary Sounders not shown 21 PU100 Emergency Stop Switch not shown 22 AT000 Timer 24h not shown WARNING T...

Страница 38: ...GGS1000 Articulated Arm Single Articulated Arm Dual Linear Arm Single Linear Arm Dual 2nd Direction Motor 1 Press Hold Gate Opening Yes P no S Change Direction P to Execute 3rd Direction Motor 2 Chang...

Страница 39: ...Remote Control Behaviour Open Only Open Stop Close Stop Open Stop Close Open Open Close Open IR 1 2 3 Behaviour IR1 2 3 CLOSE DIR IR1 2 3 OPEN DIR IR1 2 3 OPEN CLOSE DIR IR1 2 3 CLOSE DIR IMMEDIATE C...

Страница 40: ...ing TTC 20 Seconds Setting TTC 30 Seconds Setting TTC 45 Seconds Setting TTC 1 Minute Setting TTC 2 Minutes Setting TTC 3 Minutes Setting TTC 5 Minutes Disable Ram Blow 1 Second Ram Blow 2 Seconds Rev...

Страница 41: ...30 Seconds 45 Seconds 60 Seconds 90 Seconds Soft Hard Start Setting 120 Seconds 180 Seconds 240 Seconds 300 Seconds Disabled 1 Second 2 Seconds 3 Seconds 4 Seconds 5 Seconds Soft Start Enabled Hard S...

Страница 42: ...ncrease 30 Increase 50 Soft Stop Speed PW Factory Default Learned Speed Decrease 10 Decrease 20 Decrease 30 Decrease 50 Increase 10 Increase 20 Learned Speed Increase 25 Increase 50 Increase 75 Increa...

Страница 43: ...y or grifco co nz warranty Get Connected with Visit www grifco com au or www grifco co nz for more details Additional purchase of the myQ Connectivity Kit is required to enable myQ functionality DON T...

Страница 44: ...o your rights under the applicable Australian and New Zealand consumer protection laws with respect to major failures Chamberlain or its Professional Dealer will provide you with either repairs to the...

Отзывы: