D-M-ACG-122 D-Drive Relay Expansion
Module Manual
7
2-Aug-22
7. Relay Output Configuration
To configure an output of the controller to the onboard and plug-in Relay Modules, navigate to the
appropriate P.70x setting (where ‘x’ is the number of the Output to be configured) and change the saved
setting to an option in the table below:
Setting
Description
0000
Output deactivated
0001
Continuously turned on
0101
Door is Open
The message depends on the logical status of the door
0103
Door is Open
The message depends on the logical status of the door
0201
Door is Closed
The message depends on the logical status of the door
0203
Door is Closed
The message depends on the logical status of the door
0401
There is no error
0501
Courtyard light function, switched ON during opening and closing with 10 s switch off delay after
closing.
0601
Passing on detector channel 1
0602
Passing on detector channel 2
0605
Synchronous control OPEN, signal duration 0.5 seconds.
The output is active during opening, in End position OPEN and during locking in end open
position.
0606
Synchronous control CLOSE, signal duration 0.5 seconds.
The output is active during Closing, in End position Close and during locking in end position close.
0607
Synchronous control STOP, signal duration 0.5 seconds.
The output is active when the door is not moving, no end position is approached and no locking in
any end position is active.
0612
Passing on leaving detector 1
0613
Passing on leaving detector 2
0630
Forwarding Brake
0634
Forwarding, of an low Battery from the WiCab mobile Unit
0659
F.363: forwarding disturbance of the internal safety edge.
0660
Forwarding: maximum number of trips of the safety edges has been exceeded.
0665
Forwarding detector channel 3
0666
Forwarding detector channel 4
0701
Flashing during opening and closing
0703
Switched on during Opening and Closing
0801
Active during opening and closing and during active pre-warning / clearance time.
1001
Locking second door
1002
Locking second door, 1 s switch off delay
1101
Magnet voltage in end position CLOSE
The N.C. contact of the relay has to be used
1102
Magnet voltage during Closing and in end position CLOSE