SPECIFICATIONS

Measurement .................................. Electrochemical

Sample Method ............................. Diffusion

Measurement Range .................... 0 to 300 ppm

Accuracy ........................................... ±5 ppm or ±5% of reading (whichever is greater)

 

0 to 50°C (32 to 122°F), 15 to 90 %RH

Agency Approvals ......................... Senor is UL recognized for ANSI/UL-2034 and UL-2075, E240671

Operating Conditions .................. -20 to 50°C (-4 to 122°F), 15 to 90 %RH, 0.9 - 1.1 atm

Stability ............................................. <5% signal loss/year

Response Time ............................... <35 seconds for 90% step change

Typical Area Coverage ................. 700 m

2

 (7500 ft

2

) or 15m (50ft) radius

Power Supply .................................. 24 Vdc ±20% or 24 Vac ±10% (non-isolated half-wave rectified)

Consumption ..................................

Relay model:

 40 mA max

 

Non-relay Model:

 20 mA max

Output Signal .................................. 0-10 Vdc

Output Drive Capability .............. 10K Ω min

Optional Relay Contacts ............. Form C contacts (N.O. and N.C.), 5 Amps @ 250 Vac, 5 Amps @ 30 Vdc

Relay Trip Point ............................... 25, 60 or 150 ppm jumper selectable

Relay Hysteresis.............................. 3% or 9 ppm

Wiring Connections ...................... Screw terminal block (14 to 22 AWG)

Enclosure .......................................... Polycarbonate or ABS, UL94-V0, IP65 (NEMA 4X)

 

71mm W x 104mm H x 48mm D (2.8" x 4.1" x 1.9")

Approvals ......................................... CE, RoHS

Country of Origin ..............................Canada

DIMENSIONS

85mm

3.35"

71mm

2.8"

48mm

1.9"

104mm

4.1"

IN-GE-CMD5B1000XXX-002

Copyright © Greystone Energy Systems, Inc.   All Rights Reserved    Phone:  +1 506 853 3057  Web: www.greystoneenergy.com

Содержание CMD5B1000 Series

Страница 1: ...gs MOUNTING The transmitter should be mounted on a flat surface three to five feet from the floor of the area to be controlled Do not mount the sensor near doors opening windows supply air diffusers or other known air disturbances Avoid areas with vibrations or rapid temperature changes The transmitter has two integrated mounting tabs on either side of the enclosure that facilitate a 10 size screw...

Страница 2: ... used to directly control alarms ventilation fans or may be connected to digital inputs of the B A S for status monitoring OPERATION In normal operation the sensor will measure the CO level in the surrounding air and output a proportional value on the 0 10 Vdc output The CO measurement range is 0 300 ppm An optional relay can be used to indicate an alarm condition The trip point for the relay can ...

Страница 3: ... at least 1 2 hour prior to calibration Calibrate the sensor first in clean air with no CO gas present Simply adjust the ZERO pot on the sensor board until a 0 Vdc output is obtained For this case adjust the output slightly above 0Vdc and then slowly reduce the output signal to 0Vdc The output signal may be monitored with a voltmeter connected to the OUTPUT and COMMON terminals Then attach the gas...

Страница 4: ...Vdc 20 or 24 Vac 10 non isolated half wave rectified Consumption Relay model 40 mA max Non relay Model 20 mA max Output Signal 0 10 Vdc Output Drive Capability 10K Ω min Optional Relay Contacts Form C contacts N O and N C 5 Amps 250 Vac 5 Amps 30 Vdc Relay Trip Point 25 60 or 150 ppm jumper selectable Relay Hysteresis 3 or 9 ppm Wiring Connections Screw terminal block 14 to 22 AWG Enclosure Polyca...

Отзывы: